A Novel Multisensor Device for Absolute Intracardiac Pressure Measurement, Detection, and Management of Heart Failure

Overview
Date 2023 May 4
PMID 37138811
Authors
Affiliations
Soon will be listed here.
Citing Articles

Noninvasive biometric monitoring technologies for patients with heart failure.

Arriola-Montenegro J, Mutirangura P, Akram H, Tsangaris A, Koukousaki D, Tschida M Heart Fail Rev. 2024; .

PMID: 39436486 DOI: 10.1007/s10741-024-10441-7.


Non-invasive heart failure monitoring: leveraging smart scales and digital biomarkers to improve heart failure outcomes.

Wattanachayakul P, Kittipibul V, Salah H, Yaku H, Nunez J, de la Espriella R Heart Fail Rev. 2024; 29(5):1145-1156.

PMID: 39039364 DOI: 10.1007/s10741-024-10426-6.


Machine learning-based analysis of non-invasive measurements for predicting intracardiac pressures.

van Ravensberg A, Scholte N, Omar Khader A, Brugts J, Bruining N, van der Boon R Eur Heart J Digit Health. 2024; 5(3):288-294.

PMID: 38774375 PMC: 11104465. DOI: 10.1093/ehjdh/ztae021.


Photoplethysmography and intracardiac pressures: early insights from a pilot study.

Scholte N, van Ravensberg A, Edgar R, van den Enden A, Van Mieghem N, Brugts J Eur Heart J Digit Health. 2024; 5(3):379-383.

PMID: 38774368 PMC: 11104463. DOI: 10.1093/ehjdh/ztae020.


Heart Failure Remote Monitoring: A Review and Implementation How-To.

Kobe E, McVeigh T, Hameed I, Fudim M J Clin Med. 2023; 12(19).

PMID: 37834845 PMC: 10573601. DOI: 10.3390/jcm12196200.

References
1.
Xu J, Durand L, Pibarot P . A new, simple, and accurate method for non-invasive estimation of pulmonary arterial pressure. Heart. 2002; 88(1):76-80. PMC: 1767176. DOI: 10.1136/heart.88.1.76. View

2.
Castaneda D, Esparza A, Ghamari M, Soltanpur C, Nazeran H . A review on wearable photoplethysmography sensors and their potential future applications in health care. Int J Biosens Bioelectron. 2019; 4(4):195-202. PMC: 6426305. DOI: 10.15406/ijbsbe.2018.04.00125. View

3.
Bensimhon D, Alali S, Curran L, Gelbart E, Garman D, Taylor R . The use of the reds noninvasive lung fluid monitoring system to assess readiness for discharge in patients hospitalized with acute heart failure: A pilot study. Heart Lung. 2020; 50(1):59-64. DOI: 10.1016/j.hrtlng.2020.07.003. View

4.
Lindenfeld J, Zile M, Desai A, Bhatt K, Ducharme A, Horstmanshof D . Haemodynamic-guided management of heart failure (GUIDE-HF): a randomised controlled trial. Lancet. 2021; 398(10304):991-1001. DOI: 10.1016/S0140-6736(21)01754-2. View