» Articles » PMID: 38565532

In-depth Correlation Analysis Between Tear Glucose and Blood Glucose Using a Wireless Smart Contact Lens

Overview
Journal Nat Commun
Specialty Biology
Date 2024 Apr 2
PMID 38565532
Authors
Affiliations
Soon will be listed here.
Abstract

Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called 'personalized lag time'. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.

Citing Articles

Smart Contact Lenses: Disease Monitoring and Treatment.

Pan M, Zhang Z, Shang L Research (Wash D C). 2025; 8:0611.

PMID: 39931295 PMC: 11808174. DOI: 10.34133/research.0611.


Tear glucose is associated with the presence and severity of diabetic retinopathy.

Cao N, Feng L, Xu W, He F, Xiao C, Liu Y Int J Retina Vitreous. 2025; 11(1):13.

PMID: 39915852 PMC: 11800454. DOI: 10.1186/s40942-025-00636-x.


Magnetically Responsive Enzyme and Hydrogen-Bonded Organic Framework Biocomposites for Biosensing.

Carraro F, Aghito M, Dal Zilio S, Wolinski H, Doonan C, Nidetzky B Small. 2024; 20(52):e2407487.

PMID: 39580681 PMC: 11673408. DOI: 10.1002/smll.202407487.


Additively manufactured microwave sensor for glucose level detection in saliva.

Piekarz I, Skarzynski K, Piekarz B, Wincza K, Gruszczynski S, Sloma M Sci Rep. 2024; 14(1):28235.

PMID: 39548327 PMC: 11568311. DOI: 10.1038/s41598-024-79867-1.


Multimodal integrated flexible neural probe for monitoring of EEG and lactic acid.

Zhang L, Xia J, Li B, Cao Z, Dong S RSC Adv. 2024; 14(48):35520-35528.

PMID: 39507693 PMC: 11540061. DOI: 10.1039/d4ra06336h.


References
1.
Bandodkar A, Gutruf P, Choi J, Lee K, Sekine Y, Reeder J . Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat. Sci Adv. 2019; 5(1):eaav3294. PMC: 6357758. DOI: 10.1126/sciadv.aav3294. View

2.
Yang Y, Gao W . Wearable and flexible electronics for continuous molecular monitoring. Chem Soc Rev. 2018; 48(6):1465-1491. DOI: 10.1039/c7cs00730b. View

3.
Iguchi S, Kudo H, Saito T, Ogawa M, Saito H, Otsuka K . A flexible and wearable biosensor for tear glucose measurement. Biomed Microdevices. 2007; 9(4):603-9. DOI: 10.1007/s10544-007-9073-3. View

4.
Park J, Ahn D, Kim J, Cha E, Bae B, Lee S . Printing of wirelessly rechargeable solid-state supercapacitors for soft, smart contact lenses with continuous operations. Sci Adv. 2020; 5(12):eaay0764. PMC: 6957331. DOI: 10.1126/sciadv.aay0764. View

5.
Kim J, Park J, Park Y, Cha E, Ku M, An H . A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure. Nat Biomed Eng. 2021; 5(7):772-782. DOI: 10.1038/s41551-021-00719-8. View