Eyeglasses-based Tear Biosensing System: Non-invasive Detection of Alcohol, Vitamins and Glucose

Abstract

We report on a wearable tear bioelectronic platform, integrating a microfluidic electrochemical detector into an eyeglasses nose-bridge pad, for non-invasive monitoring of key tear biomarkers. The alcohol-oxidase (AOx) biosensing fluidic system allowed real-time tear collection and direct alcohol measurements in stimulated tears, leading to the first wearable platform for tear alcohol monitoring. Placed outside the eye region this fully wearable tear-sensing platform addresses drawbacks of sensor systems involving direct contact with the eye as the contact lenses platform. Integrating the wireless electronic circuitry into the eyeglasses frame thus yielded a fully portable, convenient-to-use fashionable sensing device. The tear alcohol sensing concept was demonstrated for monitoring of alcohol intake in human subjects over multiple drinking courses, displaying good correlation to parallel BAC measurements. We also demonstrate for the first time the ability to monitor tear glucose outside the eye and the utility of wearable devices for monitoring vitamin nutrients in connection to enzymatic flow detector and rapid voltammetric scanning, respectively. These developments pave the way to build an effective eyeglasses system capable of chemical tear analysis.

Citing Articles

Tear glucose is associated with the presence and severity of diabetic retinopathy.

Cao N, Feng L, Xu W, He F, Xiao C, Liu Y Int J Retina Vitreous. 2025; 11(1):13.

PMID: 39915852 PMC: 11800454. DOI: 10.1186/s40942-025-00636-x.


A bibliometric and visualization analysis of electrochemical biosensors for early diagnosis of eye diseases.

Zhang F, Xu W, Deng Z, Huang J Front Med (Lausanne). 2025; 11:1487981.

PMID: 39867928 PMC: 11757256. DOI: 10.3389/fmed.2024.1487981.


Next-Generation Potentiometric Sensors: A Review of Flexible and Wearable Technologies.

Fathy M, Buhlmann P Biosensors (Basel). 2025; 15(1).

PMID: 39852102 PMC: 11764208. DOI: 10.3390/bios15010051.


MXene-Graphene Oxide Heterostructured Films for Enhanced Metasurface Plasmonic Biosensing in Continuous Glucose Monitoring.

Li R, Fan H, Chen Y, Yin S, Liu G, Li Y Adv Sci (Weinh). 2024; 12(4):e2410376.

PMID: 39569760 PMC: 11775529. DOI: 10.1002/advs.202410376.


Additively manufactured microwave sensor for glucose level detection in saliva.

Piekarz I, Skarzynski K, Piekarz B, Wincza K, Gruszczynski S, Sloma M Sci Rep. 2024; 14(1):28235.

PMID: 39548327 PMC: 11568311. DOI: 10.1038/s41598-024-79867-1.


References
1.
Karns-Wright T, Roache J, Hill-Kapturczak N, Liang Y, Mullen J, Dougherty D . Time Delays in Transdermal Alcohol Concentrations Relative to Breath Alcohol Concentrations. Alcohol Alcohol. 2016; 52(1):35-41. PMC: 5169032. DOI: 10.1093/alcalc/agw058. View

2.
Giles H, Sandrin S, Kapur B, Thiessen J . Ethanol vapours above lacrimal fluid in the rabbit. Can J Physiol Pharmacol. 1987; 65(12):2491-3. DOI: 10.1139/y87-395. View

3.
Campbell A, Kim J, Wang J . Wearable Electrochemical Alcohol Biosensors. Curr Opin Electrochem. 2019; 10:126-135. PMC: 6407881. DOI: 10.1016/j.coelec.2018.05.014. View

4.
Vinu Mohan A, Windmiller J, Mishra R, Wang J . Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays. Biosens Bioelectron. 2017; 91:574-579. PMC: 5323319. DOI: 10.1016/j.bios.2017.01.016. View

5.
Kownacka A, Vegelyte D, Joosse M, Anton N, Toebes B, Lauko J . Clinical Evidence for Use of a Noninvasive Biosensor for Tear Glucose as an Alternative to Painful Finger-Prick for Diabetes Management Utilizing a Biopolymer Coating. Biomacromolecules. 2018; 19(11):4504-4511. PMC: 6234487. DOI: 10.1021/acs.biomac.8b01429. View