Fast-Response Variable-Stiffness Magnetic Catheters for Minimally Invasive Surgery

Overview
Journal Adv Sci (Weinh)
Date 2024 Jan 16
PMID 38225742
Authors
Affiliations
Soon will be listed here.
Abstract

In minimally invasive surgery, such as cardiac ablation, magnetically steered catheters made of variable-stiffness materials can enable higher dexterity and higher force application to human tissue. However, the long transition time between soft and rigid states leads to a significant increase in procedure duration. Here, a fast-response, multisegmented catheter is described for minimally invasive surgery made of variable-stiffness thread (FRVST) that encapsulates a helical cooling channel. The rapid stiffness change in the FRVST, composed of a nontoxic shape memory polymer, is achieved by an active cooling system that pumps water through the helical channel. The FRVST displays a 66 times stiffness change and a 26 times transition enhancement compare with the noncooled version. The catheter allows for selective bending of each segment up to 127° in air and up to 76° in water under an 80 mT external magnetic field. The inner working channel can be used for cooling an ablation tip during a procedure and for information exchange via the deployment of wires or surgical tools.

Citing Articles

A compliant metastructure design with reconfigurability up to six degrees of freedom.

Yang H, Patel D, Johnson T, Zhong K, Olson G, Majidi C Nat Commun. 2025; 16(1):719.

PMID: 39820271 PMC: 11739503. DOI: 10.1038/s41467-024-55591-2.


Multi-Section Magnetic Soft Robot with Multirobot Navigation System for Vasculature Intervention.

Li Z, Xu Q Cyborg Bionic Syst. 2024; 5:0188.

PMID: 39610760 PMC: 11602701. DOI: 10.34133/cbsystems.0188.


Thermally Drawn Polymeric Catheters for MR-Guided Cardiovascular Intervention.

Abdelaziz M, Tian L, Lottner T, Reiss S, Heidt T, Maier A Adv Sci (Weinh). 2024; 11(45):e2407704.

PMID: 39403885 PMC: 11615795. DOI: 10.1002/advs.202407704.


Design, Modeling, and Experimental Validation of an Active Microcatheter Driven by Shape Memory Effects.

Li C, Zhang X, Ren Z, Wang J, Sun S, Fu J Micromachines (Basel). 2024; 15(5).

PMID: 38793176 PMC: 11123389. DOI: 10.3390/mi15050603.


Silicone-based highly stretchable multifunctional fiber pumps.

Kanno R, Shimizu K, Murakami K, Shibahara Y, Ogawa N, Akai H Sci Rep. 2024; 14(1):4618.

PMID: 38409217 PMC: 10897224. DOI: 10.1038/s41598-024-55472-0.


References
1.
Chun J, Ernst S, Matthews S, Schmidt B, Bansch D, Boczor S . Remote-controlled catheter ablation of accessory pathways: results from the magnetic laboratory. Eur Heart J. 2007; 28(2):190-5. DOI: 10.1093/eurheartj/ehl447. View

2.
Neradi D, Kumar V, Kumar S, Sodavarapu P, Goni V, Dhatt S . Minimally Invasive Surgery versus Open Surgery for Adolescent Idiopathic Scoliosis: A Systematic Review and Meta-Analysis. Asian Spine J. 2021; 16(2):279-289. PMC: 9066260. DOI: 10.31616/asj.2020.0605. View

3.
Houmsse M, Daoud E . Biophysics and clinical utility of irrigated-tip radiofrequency catheter ablation. Expert Rev Med Devices. 2011; 9(1):59-70. DOI: 10.1586/erd.11.42. View

4.
Tangwongsan C, Will J, Webster J, Meredith Jr K, Mahvi D . In vivo measurement of swine endocardial convective heat transfer coefficient. IEEE Trans Biomed Eng. 2004; 51(8):1478-86. DOI: 10.1109/TBME.2004.828035. View

5.
Le H, Phan P, Lin C, Jiajun L, Phee S . A Temperature-Dependent, Variable-Stiffness Endoscopic Robotic Manipulator with Active Heating and Cooling. Ann Biomed Eng. 2020; 48(6):1837-1849. DOI: 10.1007/s10439-020-02495-z. View