Estimating Anchor-based Minimal Important Change Using Longitudinal Confirmatory Factor Analysis

Overview
Journal Qual Life Res
Date 2023 Dec 27
PMID 38151593
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The minimal important change (MIC) is defined as the smallest within-individual change in a patient-reported outcome measure (PROM) that patients on average perceive as important. We describe a method to estimate this value based on longitudinal confirmatory factor analysis (LCFA). The method is evaluated and compared with a recently published method based on longitudinal item response theory (LIRT) in simulated and real data. We also examined the effect of sample size on bias and precision of the estimate.

Methods: We simulated 108 samples with various characteristics in which the true MIC was simulated as the mean of individual MICs, and estimated MICs based on LCFA and LIRT. Additionally, both MICs were estimated in existing PROMIS Pain Behavior data from 909 patients. In another set of 3888 simulated samples with sample sizes of 125, 250, 500, and 1000, we estimated LCFA-based MICs.

Results: The MIC was equally well recovered with the LCFA-method as using the LIRT-method, but the LCFA analyses were more than 50 times faster. In the Pain Behavior data (with higher scores indicating more pain behavior), an LCFA-based MIC for improvement was estimated to be 2.85 points (on a simple sum scale ranging 14-42), whereas the LIRT-based MIC was estimated to be 2.60. The sample size simulations showed that smaller sample sizes decreased the precision of the LCFA-based MIC and increased the risk of model non-convergence.

Conclusion: The MIC can accurately be estimated using LCFA, but sample sizes need to be preferably greater than 125.

Citing Articles

A weighted predictive modeling method for estimating thresholds of meaningful within-individual change for patient-reported outcomes.

Zhao C, Yan M, Xu X, Ou C Qual Life Res. 2025; .

PMID: 39969677 DOI: 10.1007/s11136-025-03924-z.


Advances in the calculation of minimal important change estimates for patient-reported outcome measures.

Roos E Nat Rev Rheumatol. 2025; 21(2):75-76.

PMID: 39743612 DOI: 10.1038/s41584-024-01214-5.


Effect of present state bias on minimal important change estimates: a simulation study.

Terluin B, Fromy P, Trigg A, Terwee C, Bjorner J Qual Life Res. 2024; 33(11):2963-2973.

PMID: 39174866 PMC: 11541299. DOI: 10.1007/s11136-024-03763-4.


Estimating anchor-based minimal important change using longitudinal confirmatory factor analysis.

Terluin B, Trigg A, Fromy P, Schuller W, Terwee C, Bjorner J Qual Life Res. 2023; 33(4):963-973.

PMID: 38151593 DOI: 10.1007/s11136-023-03577-w.

References
1.
Jaeschke R, Singer J, Guyatt G . Measurement of health status. Ascertaining the minimal clinically important difference. Control Clin Trials. 1989; 10(4):407-15. DOI: 10.1016/0197-2456(89)90005-6. View

2.
Terwee C, Peipert J, Chapman R, Lai J, Terluin B, Cella D . Minimal important change (MIC): a conceptual clarification and systematic review of MIC estimates of PROMIS measures. Qual Life Res. 2021; 30(10):2729-2754. PMC: 8481206. DOI: 10.1007/s11136-021-02925-y. View

3.
Terluin B, Eekhout I, Terwee C . The anchor-based minimal important change, based on receiver operating characteristic analysis or predictive modeling, may need to be adjusted for the proportion of improved patients. J Clin Epidemiol. 2017; 83:90-100. DOI: 10.1016/j.jclinepi.2016.12.015. View

4.
Vanier A, Sebille V, Blanchin M, Hardouin J . The minimal perceived change: a formal model of the responder definition according to the patient's meaning of change for patient-reported outcome data analysis and interpretation. BMC Med Res Methodol. 2021; 21(1):128. PMC: 8215756. DOI: 10.1186/s12874-021-01307-9. View

5.
Bjorner J, Terluin B, Trigg A, Hu J, Brady K, Griffiths P . Establishing thresholds for meaningful within-individual change using longitudinal item response theory. Qual Life Res. 2022; 32(5):1267-1276. PMC: 10123029. DOI: 10.1007/s11136-022-03172-5. View