» Articles » PMID: 37958592

The Dual Luminescence Lifetime PH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells

Overview
Journal Int J Mol Sci
Publisher MDPI
Date 2023 Nov 14
PMID 37958592
Authors
Affiliations
Soon will be listed here.
Abstract

The oxygenation of cells and tissues and acidification of the cellular endolysosomal system are among the major factors that ensure normal functioning of an organism and are violated in various pathologies. Recording of these parameters and their changes under various conditions is an important task for both basic research and clinical applications. In the present work, we utilized internalizable dual pH/O lifetime sensor (Ir-HSA-FITC) based on the covalent conjugation of human serum albumin (HSA) with fluorescein isothiocyanate (FITC) as pH sensor and an orthometalated iridium complex as O sensor. The probe was tested for simultaneous detection of acidification level and oxygen concentration in endolysosomes of endometrial mesenchymal stem/stromal cells (enMSCs) cultivated as 2D monolayers and 3D spheroids. Using a combined FLIM/PLIM approach, we found that due to high autofluorescence of enMSCs FITC lifetime signal in control cells was insufficient to estimate pH changes. However, using flow cytometry and confocal microscopy, we managed to detect the FITC signal response to inhibition of endolysosomal acidification by Bafilomycin A1. The iridium chromophore phosphorescence was detected reliably by all methods used. It was demonstrated that the sensor, accumulated in endolysosomes for 24 h, disappeared from proliferating 2D enMSCs by 72 h, but can still be recorded in non-proliferating spheroids. PLIM showed high sensitivity and responsiveness of iridium chromophore phosphorescence to experimental hypoxia both in 2D and 3D cultures. In spheroids, the phosphorescence signal was detected at a depth of up to 60 μm using PLIM and showed a gradient in the intracellular O level towards their center.

Citing Articles

Shining New Light on Biological Systems: Luminescent Transition Metal Complexes for Bioimaging and Biosensing Applications.

Lee L, Lo K Chem Rev. 2024; 124(15):8825-9014.

PMID: 39052606 PMC: 11328004. DOI: 10.1021/acs.chemrev.3c00629.

References
1.
Schaefer P, Kalinina S, Rueck A, von Arnim C, von Einem B . NADH Autofluorescence-A Marker on its Way to Boost Bioenergetic Research. Cytometry A. 2018; 95(1):34-46. DOI: 10.1002/cyto.a.23597. View

2.
Lavrentieva A, Hoffmann A, Lee-Thedieck C . Limited Potential or Unfavorable Manipulations? Strategies Toward Efficient Mesenchymal Stem/Stromal Cell Applications. Front Cell Dev Biol. 2020; 8:316. PMC: 7248306. DOI: 10.3389/fcell.2020.00316. View

3.
Jahn K, Buschmann V, Hille C . Simultaneous Fluorescence and Phosphorescence Lifetime Imaging Microscopy in Living Cells. Sci Rep. 2015; 5:14334. PMC: 4585718. DOI: 10.1038/srep14334. View

4.
Samandarsangari M, Kozina D, Sokolov V, Komarova A, Shirmanova M, Kritchenkov I . Biocompatible Phosphorescent O Sensors Based on Ir(III) Complexes for In Vivo Hypoxia Imaging. Biosensors (Basel). 2023; 13(7). PMC: 10377268. DOI: 10.3390/bios13070680. View

5.
Samal J, Rangasami V, Samanta S, Varghese O, Oommen O . Discrepancies on the Role of Oxygen Gradient and Culture Condition on Mesenchymal Stem Cell Fate. Adv Healthc Mater. 2021; 10(6):e2002058. PMC: 11469238. DOI: 10.1002/adhm.202002058. View