» Articles » PMID: 37637507

Automated Bidirectional Coupling of Multiscale Models of Aerosol Dosimetry: Validation with Subject-specific Deposition Data

Overview
Journal J Aerosol Sci
Date 2023 Aug 28
PMID 37637507
Authors
Affiliations
Soon will be listed here.
Abstract

Assessing the toxicity of airborne particulate matter or the efficacy of inhaled drug depends upon accurate estimates of deposited fraction of inhaled materials. approaches can provide important insights into site- or airway-specific deposition of inhaled aerosols in the respiratory system. In this study, we improved on our recently developed 3D/1D model that simulate aerosol transport and deposition in the whole lung over multiple breath cycles ( 151:105647). A subject-specific multiscale lung model of a healthy male subject using computational fluid-particle dynamics (CFPD) in a 3D model of the oral cavity through the large bronchial airways entering each lobe was bidirectionally coupled with a recently improved Multiple Path Particle Dosimetry (MPPD) model to predict aerosol deposition over the entire respiratory tract over multiple breaths for four conditions matching experimental aerosol exposures in the same subject from which the model was developed. These include two particle sizes (1 and 2.9 μm) and two subject-specific breathing rates of ~300 ml/s (slow breathing) and ~750 ml/s (fast breathing) at a target tidal volume of 1 L. predictions of retained fraction were 0.31 and 0.29 for 1 μm and 0.66 and 0.62 for 2.9 μm during slow and fast breathing, respectively, and compared well with experimental data (1 μm: 0.31±0.01 (slow) and 0.27±0.01 (fast), 2.9 μm: 0.63±0.03 (slow) and 0.68±0.02 (fast)). These results provide a great deal of confidence in the validity and reliability of our approach.

Citing Articles

Evaluation of a non-animal toolbox informed by adverse outcome pathways for human inhalation safety.

de Avila R, Muller I, Barlow H, Middleton A, Theiventhran M, Basili D Front Toxicol. 2025; 7:1426132.

PMID: 40061084 PMC: 11885506. DOI: 10.3389/ftox.2025.1426132.


Modeling aerosol bolus inhalations in the human lung with the Multiple Path Particle Deposition model: Comparison with experimental data.

Asgharian B, Price O, Borojeni A, Kuprat A, Colby S, Singh R J Aerosol Sci. 2025; 185.

PMID: 40060110 PMC: 11884729. DOI: 10.1016/j.jaerosci.2025.106547.


Subject-Specific Multi-Scale Modeling of the Fate of Inhaled Aerosols.

Kuprat A, Feng Y, Corley R, Darquenne C J Aerosol Sci. 2024; 183.

PMID: 39678160 PMC: 11636312. DOI: 10.1016/j.jaerosci.2024.106471.


The effects of airway disease on the deposition of inhaled drugs.

Darquenne C, Corcoran T, Lavorini F, Sorano A, Usmani O Expert Opin Drug Deliv. 2024; 21(8):1175-1190.

PMID: 39136493 PMC: 11412782. DOI: 10.1080/17425247.2024.2392790.


Recent Developments in Aerosol Pulmonary Drug Delivery: New Technologies, New Cargos, and New Targets.

Woodward I, Fromen C Annu Rev Biomed Eng. 2024; 26(1):307-330.

PMID: 38424089 PMC: 11222059. DOI: 10.1146/annurev-bioeng-110122-010848.


References
1.
Sa R, Zeman K, Bennett W, Prisk G, Darquenne C . Effect of Posture on Regional Deposition of Coarse Particles in the Healthy Human Lung. J Aerosol Med Pulm Drug Deliv. 2015; 28(6):423-31. DOI: 10.1089/jamp.2014.1189. View

2.
Kolanjiyil A, Kleinstreuer C . Computationally efficient analysis of particle transport and deposition in a human whole-lung-airway model. Part I: Theory and model validation. Comput Biol Med. 2016; 79:193-204. DOI: 10.1016/j.compbiomed.2016.10.020. View

3.
Longest P, Tian G, Walenga R, Hindle M . Comparing MDI and DPI aerosol deposition using in vitro experiments and a new stochastic individual path (SIP) model of the conducting airways. Pharm Res. 2012; 29(6):1670-88. DOI: 10.1007/s11095-012-0691-y. View

4.
Darquenne C, West J, Prisk G . Dispersion of 0.5- to 2-micron aerosol in microG and hypergravity as a probe of convective inhomogeneity in the lung. J Appl Physiol (1985). 1999; 86(4):1402-9. DOI: 10.1152/jappl.1999.86.4.1402. View

5.
Chan H, Daviskas E, Eberl S, Robinson M, BAUTOVICH G, Young I . Deposition of aqueous aerosol of technetium-99m diethylene triamine penta-acetic acid generated and delivered by a novel system (AERx) in healthy subjects. Eur J Nucl Med. 1999; 26(4):320-7. DOI: 10.1007/s002590050393. View