» Articles » PMID: 37237696

Computational Modeling of Diffusion-Based Delamination for Active Implantable Medical Devices

Overview
Date 2023 May 27
PMID 37237696
Authors
Affiliations
Soon will be listed here.
Abstract

Delamination at heterogeneous material interfaces is one of the most prominent failure modes in active implantable medical devices (AIMDs). A well-known example of an AIMD is the cochlear implant (CI). In mechanical engineering, a multitude of testing procedures are known whose data can be used for detailed modeling with respect to digital twins. Detailed, complex models for digital twins are still lacking in bioengineering since body fluid infiltration occurs both into the polymer substrate and along the metal-polymer interfaces. For a newly developed test for an AIMD or CI composed of silicone rubber and metal wiring or electrodes, a mathematical model of these mechanisms is presented. It provides a better understanding of the failure mechanisms in such devices and their validation against real-life data. The implementation utilizes COMSOL Multiphysics, consisting of a volume diffusion part and models for interface diffusion (and delamination). For a set of experimental data, the necessary diffusion coefficient could be derived. A subsequent comparison of experimental and modeling results showed a good qualitative and functional match. The delamination model follows a mechanical approach. The results of the interface diffusion model, which follows a substance transport-based approach, show a very good approximation to the results of previous experiments.

References
1.
Cote M, Ferron P, Bergeron F, Bussieres R . Cochlear reimplantation: causes of failure, outcomes, and audiologic performance. Laryngoscope. 2007; 117(7):1225-35. DOI: 10.1097/MLG.0b013e31805c9a06. View

2.
Foggia M, Quevedo R, Hansen M . Intracochlear fibrosis and the foreign body response to cochlear implant biomaterials. Laryngoscope Investig Otolaryngol. 2020; 4(6):678-683. PMC: 6929576. DOI: 10.1002/lio2.329. View

3.
Shi L, Zhu G, Ma D, Zhu C, Chen J, Qian X . Delayed postoperative complications in 624 consecutive cochlear implantation cases. Acta Otolaryngol. 2021; 141(7):663-670. DOI: 10.1080/00016489.2021.1942194. View

4.
Stover T, Lenarz T . Biomaterials in cochlear implants. GMS Curr Top Otorhinolaryngol Head Neck Surg. 2011; 8:Doc10. PMC: 3199815. DOI: 10.3205/cto000062. View

5.
Stieglitz T . [Neural prostheses and neuromodulation : Research and clinical practice in therapy and rehabilitation]. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz. 2010; 53(8):783-90. DOI: 10.1007/s00103-010-1093-0. View