Despite the technological progress made with cochlear implants (CI), impedances and their diagnosis remain a focus of interest. Increases in impedance have been related to technical defects of the electrode as well as inflammatory and/or fibrosis along the electrode. Recent studies have demonstrated highly increased impedances as the result of corroded platinum (Pt) electrode contacts. This in vitro study examined the effects of Pt ions and compounds generated by corrosion of the electrode contacts of a human CI on cell metabolism. Since traces of solid Pt in surrounding cochlear tissues have been reported, the impact of commercially available Pt nanoparticles (Pt-NP, size 3 nm) on the cell culture model was also determined. For this purpose, the electrode contacts were electrically stimulated in a 0.5% aqueous NaCl solution for four weeks and the mass fraction of the platinum dissolute (Pt-Diss) was determined by mass spectrometry (ICP-MS). Metabolic activity of the murine fibroblasts (NIH 3T3) and the human neuroblastoma (SH-SY5Y) cells was determined using the WST-1 assay following exposure to Pt-Diss and Pt-NP. It was found that 5-50 μg/ml of the Pt-NP did not affect the viability of both cell types. In contrast, 100 μg/ml of the nanoparticles caused significant loss in metabolic activity. Furthermore, transmission electron microscopy (TEM) revealed mitochondrial swelling in both cell types indicating cytotoxicity. Additionally, TEM demonstrated internalized Pt-NP in NIH 3T3 cells in a concentration dependent manner, whereas endocytosis in SH-SY5Y cells was virtually absent. In comparison with the Pt-NP, the corrosion products (Pt-Diss) with concentrations between 1.64 μg/ml and 8.2 μg/ml induced cell death in both cell lines in a concentration dependent manner. TEM imaging revealed both mitochondrial disintegration and swelling of the endoplasmic reticulum, suggesting that Pt ions trigger cytotoxicity in both NIH 3T3 and SH-SY5Y cell lines by interacting with the respiratory chain.
Berger E, Brandes G, Kaiser O, Reifenrath J, Lenarz T, Wissel K PLoS One. 2024; 19(7):e0307973.
PMID: 39058727 PMC: 11280268. DOI: 10.1371/journal.pone.0307973.
Investigating mechanical deformation's role in cochlear implant durability.
Blank T, Ahrens A, Klose C, Canadinc D, Lenarz T, Maier H PLoS One. 2024; 19(7):e0306613.
PMID: 38980854 PMC: 11232988. DOI: 10.1371/journal.pone.0306613.
Engineered heart tissue: Design considerations and the state of the art.
Gokhan I, Blum T, Campbell S Biophys Rev (Melville). 2024; 5(2):021308.
PMID: 38912258 PMC: 11192576. DOI: 10.1063/5.0202724.
Li L, Jiang C, Li L Micromachines (Basel). 2024; 15(1).
PMID: 38258189 PMC: 10821385. DOI: 10.3390/mi15010070.
Bioelectronic Neural Interfaces: Improving Neuromodulation Through Organic Conductive Coatings.
Duan W, Aregueta Robles U, Poole-Warren L, Esrafilzadeh D Adv Sci (Weinh). 2023; 11(27):e2306275.
PMID: 38115740 PMC: 11251570. DOI: 10.1002/advs.202306275.