» Articles » PMID: 36832165

Spectral CT Imaging of Prosthetic Valve Embolization After Transcatheter Aortic Valve Implantation

Abstract

Transcatheter heart valve (THV) embolization is a rare complication of transcatheter aortic valve implantation (TAVI) generally caused by malpositioning, sizing inaccuracies and pacing failures. The consequences are related to the site of embolization, ranging from a silent clinical picture when the device is stably anchored in the descending aorta to potentially fatal outcomes (e.g., obstruction of flow to vital organs, aortic dissection, thrombosis, etc.). Here, we present the case of a 65-year-old severely obese woman affected by severe aortic valve stenosis who underwent TAVI complicated by embolization of the device. The patient underwent spectral CT angiography that allowed for improved image quality by means of virtual monoenergetic reconstructions, permitting optimal pre-procedural planning. She was successfully re-treated with implantation of a second prosthetic valve a few weeks later.

Citing Articles

Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability.

Booz C, Bucolo G, DAngelo T, Mazziotti S, Lanzafame L, Yel I Radiol Med. 2024; 129(11):1633-1643.

PMID: 39287697 PMC: 11554704. DOI: 10.1007/s11547-024-01889-6.


Pre-TAVI imaging: an Italian survey by the CT PRotocol optimization (CT-PRO) group.

DAngelo T, Lanzafame L, Liguori C, Mantini C, Russo V, Palumbo P Int J Cardiovasc Imaging. 2024; 40(4):831-839.

PMID: 38263535 PMC: 11052815. DOI: 10.1007/s10554-024-03052-8.


The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair.

Kazimierczak W, Nowak E, Kazimierczak N, Jankowski T, Jankowska A, Serafin Z Heliyon. 2023; 9(10):e20700.

PMID: 37876478 PMC: 10590777. DOI: 10.1016/j.heliyon.2023.e20700.

References
1.
Nashef S, Roques F, Sharples L, Nilsson J, Smith C, Goldstone A . EuroSCORE II. Eur J Cardiothorac Surg. 2012; 41(4):734-44. DOI: 10.1093/ejcts/ezs043. View

2.
DAngelo T, Cicero G, Mazziotti S, Ascenti G, Albrecht M, Martin S . Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications. Br J Radiol. 2019; 92(1098):20180546. PMC: 6592074. DOI: 10.1259/bjr.20180546. View

3.
Martin S, Wichmann J, Scholtz J, Leithner D, DAngelo T, Weyer H . Noise-Optimized Virtual Monoenergetic Dual-Energy CT Improves Diagnostic Accuracy for the Detection of Active Arterial Bleeding of the Abdomen. J Vasc Interv Radiol. 2017; 28(9):1257-1266. DOI: 10.1016/j.jvir.2017.06.011. View

4.
Leithner D, Mahmoudi S, Wichmann J, Martin S, Lenga L, Albrecht M . Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis. Eur J Radiol. 2018; 99:111-117. DOI: 10.1016/j.ejrad.2017.12.024. View

5.
Lenga L, Albrecht M, Othman A, Martin S, Leithner D, DAngelo T . Monoenergetic Dual-energy Computed Tomographic Imaging: Cardiothoracic Applications. J Thorac Imaging. 2017; 32(3):151-158. DOI: 10.1097/RTI.0000000000000259. View