Noise-Optimized Virtual Monoenergetic Dual-Energy CT Improves Diagnostic Accuracy for the Detection of Active Arterial Bleeding of the Abdomen
Overview
Radiology
Authors
Affiliations
Purpose: To evaluate diagnostic accuracy of a noise-optimized virtual monoenergetic imaging (VMI+) reconstruction technique for detection of active arterial abdominal bleeding on dual-energy (DE) CT angiography compared with standard image reconstruction.
Materials And Methods: DE CT angiography data sets of 71 patients (46 men; age 63.6 y ± 13.3) with suspected arterial bleeding of the abdomen or pelvis were reconstructed with standard linearly blended (F_0.5), VMI+, and traditional virtual monoenergetic imaging (VMI) algorithms in 10-keV increments from 40 to 100 keV. Attenuation measurements were performed in the descending aorta, area of hemorrhage, and feeding artery to calculate contrast-to-noise ratios (CNRs) in patients with active arterial bleeding. Based on quantitative image quality results, the best series for each reconstruction technique were chosen to analyze the diagnostic performance of 3 blinded radiologists.
Results: DE CT angiography showed acute arterial bleeding in 36 patients. Mean CNR was superior in 40-keV VMI+ compared with VMI series (all P < .001), which showed highest CNRs in 70-keV VMI and F_0.5 (21.6 ± 7.9, 12.9 ± 4.7, and 10.4 ± 3.6) images. Area under the curve analysis for detection of arterial bleeding showed significantly superior (P < .001) results for 40-keV VMI+ (0.963) compared with 70-keV VMI (0.775) and F_0.5 (0.817) series.
Conclusions: Diagnostic accuracy in patients with active arterial bleeding of the abdomen can be significantly improved using VMI+ reconstructions at 40 keV compared with standard linearly blended and traditional VMI series in DE CT angiography.
Zhang H, Xing Y, Wang L, Hu Y, Xu Z, Chen H J Imaging Inform Med. 2024; .
PMID: 39455541 DOI: 10.1007/s10278-024-01232-5.
DAngelo T, Bucolo G, Yel I, Koch V, Gruenewald L, Martin S Radiol Med. 2024; 129(11):1611-1621.
PMID: 39405018 PMC: 11554692. DOI: 10.1007/s11547-024-01898-5.
Investigation of abdominal artery delineation by photon-counting detector CT.
Ota T, Onishi H, Itoh T, Fukui H, Tsuboyama T, Nakamoto A Radiol Med. 2024; 129(9):1265-1274.
PMID: 39043979 PMC: 11379784. DOI: 10.1007/s11547-024-01858-z.
Kazimierczak W, Kazimierczak N, Wilamowska J, Wojtowicz O, Nowak E, Serafin Z Sci Rep. 2024; 14(1):3845.
PMID: 38360941 PMC: 10869818. DOI: 10.1038/s41598-024-54502-1.
Kazimierczak W, Nowak E, Kazimierczak N, Jankowski T, Jankowska A, Serafin Z Heliyon. 2023; 9(10):e20700.
PMID: 37876478 PMC: 10590777. DOI: 10.1016/j.heliyon.2023.e20700.