» Articles » PMID: 36386296

Investigating the Feasibility of a Hand-held Photoacoustic Imaging Probe for Margin Assessment During Breast Conserving Surgery

Overview
Journal Photoacoustics
Date 2022 Nov 17
PMID 36386296
Authors
Affiliations
Soon will be listed here.
Abstract

Approximately 19 % of breast cancer patients undergoing breast conserving surgery (BCS) must return for a secondary surgery due to incomplete tumour removal. Our previous work demonstrated that the lower lipid content, characteristic of tumour tissue, was observed as regions of hypo-intense photoacoustic (PA) contrast. The goal of this work was to evaluate feasibility of a low-frequency, hand-held PA imaging probe for surgical margin assessment based on lipid content differences. Here, we describe (i) the design of a prototype hand-held PA imaging probe, (ii) the effect of limited-bandwidth on image contrast, (iii) accuracy towards hypo-intense contrast detection, (iv) the limited-view characteristics of the single sensor design, and (iv) early imaging results of an ex-vivo breast cancer specimen. The probe incorporates a single polyvinylidene fluoride acoustic sensor, a 1-to-4 optical fibre bundle and a polycarbonate axicon lens for light delivery. Imaging results on phantoms designed to mimic positive margins demonstrated the ability to detect gaps in optical absorption as small as 1 mm in width. Compared to images from a near full-view PAI system, the hand-held PAI probe had higher signal to noise ratio but suffered from negativity image artifacts. Lumpectomy specimen imaging showed that strong signals can be obtained from the fatty tissue. Taken together, the results show this imaging approach with a hand-held probe has potential for detection of residual breast cancer tissue during BCS; however, more work is needed to reduce the size of the probe to fit within the surgical cavity.

Citing Articles

Development of a cost-effective compact diode-laser-based photoacoustic sensing instrument for breast tissue diagnosis.

Khan S, Mukhopadhyay S, Vasudevan S, Goel G, Joshi D, Kapoor N J Biomed Opt. 2024; 29(1):017002.

PMID: 38213472 PMC: 10783045. DOI: 10.1117/1.JBO.29.1.017002.

References
1.
Li R, Wang P, Lan L, Lloyd Jr F, Goergen C, Chen S . Assessing breast tumor margin by multispectral photoacoustic tomography. Biomed Opt Express. 2015; 6(4):1273-81. PMC: 4399666. DOI: 10.1364/BOE.6.001273. View

2.
Fisher S, Yasui Y, Dabbs K, Winget M . Re-excision and survival following breast conserving surgery in early stage breast cancer patients: a population-based study. BMC Health Serv Res. 2018; 18(1):94. PMC: 5806481. DOI: 10.1186/s12913-018-2882-7. View

3.
Park B, Han M, Park J, Kim T, Ryu H, Seo Y . A photoacoustic finder fully integrated with a solid-state dye laser and transparent ultrasound transducer. Photoacoustics. 2021; 23:100290. PMC: 8358697. DOI: 10.1016/j.pacs.2021.100290. View

4.
Li R, Lan L, Xia Y, Wang P, Han L, Dunnington G . High-speed Intraoperative Assessment of Breast Tumor Margins by Multimodal Ultrasound and Photoacoustic Tomography. Med Devices Sens. 2019; 1(3). PMC: 6703831. DOI: 10.1002/mds3.10018. View

5.
Diot G, Metz S, Noske A, Liapis E, Schroeder B, Ovsepian S . Multispectral Optoacoustic Tomography (MSOT) of Human Breast Cancer. Clin Cancer Res. 2017; 23(22):6912-6922. DOI: 10.1158/1078-0432.CCR-16-3200. View