Closed-loop Insulin Delivery: Update on the State of the Field and Emerging Technologies

Overview
Specialties Pharmacology
Radiology
Date 2022 Nov 4
PMID 36331211
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Over the last five years, closed-loop insulin delivery systems have transitioned from research-only to real-life use. A number of systems have been commercialized and are increasingly used in clinical practice. Given the rapidity of new developments in the field, understanding the capabilities and key similarities and differences of current systems can be challenging. This review aims to provide an update on the state of the field of closed-loop insulin delivery systems, including emerging technologies.

Areas Covered: We summarize key clinical safety and efficacy evidence of commercial and emerging insulin-only hybrid closed-loop systems for type 1 diabetes. A literature search was conducted and clinical trials using closed-loop systems during free-living conditions were identified to report on safety and efficacy data. We comment on emerging technologies and adjuncts for closed-loop systems, as well as non-technological priorities in closed-loop insulin delivery.

Expert Opinion: Commercial hybrid closed-loop insulin delivery systems are efficacious, consistently improving glycemic control when compared to standard therapy. Challenges remain in widespread adoption due to clinical inertia and the lack of resources to embrace technological developments by health care professionals.

Citing Articles

Effects of switching from MiniMed™ 640G to 770G on continuous glucose monitoring metrics and DTR-QOL scores: An observational study of Japanese people with type 1 diabetes mellitus.

Kogai T, Sato J, Yasuda H, Ayame T, Ozaki A, Takagi E J Diabetes Investig. 2024; 16(2):326-333.

PMID: 39513544 PMC: 11786187. DOI: 10.1111/jdi.14350.


Advancements in Insulin Pumps: A Comprehensive Exploration of Insulin Pump Systems, Technologies, and Future Directions.

Rimon M, Hasan M, Hassan M, Cesmeci S Pharmaceutics. 2024; 16(7).

PMID: 39065641 PMC: 11279469. DOI: 10.3390/pharmaceutics16070944.


Efficacy of automated insulin delivery in pregnant women with type 1 diabetes: a meta-analysis and trial sequential analysis of randomized controlled trials.

Teixeira T, Godoi A, Romeiro P, Novaes J, Faria F, Pereira S Acta Diabetol. 2024; 61(7):831-840.

PMID: 38700546 DOI: 10.1007/s00592-024-02284-3.


Effects of hybrid closed-loop system on glycemic control and psychological aspects in persons with type 1 diabetes treated with sensor-augmented pump: A prospective single-center observational study.

Akiyama T, Yamakawa T, Orime K, Ichikawa M, Harada M, Netsu T J Diabetes Investig. 2023; 15(2):219-226.

PMID: 37934090 PMC: 10804894. DOI: 10.1111/jdi.14103.


Glucose control and psychosocial outcomes with use of automated insulin delivery for 12 to 96 weeks in type 1 diabetes: a meta-analysis of randomised controlled trials.

Godoi A, Marques I, Padrao E, Mahesh A, Hespanhol L, Riceto Loyola Junior J Diabetol Metab Syndr. 2023; 15(1):190.

PMID: 37759290 PMC: 10537468. DOI: 10.1186/s13098-023-01144-4.


References
1.
Thabit H, Prabhu J, Mubita W, Fullwood C, Azmi S, Urwin A . Use of Factory-Calibrated Real-time Continuous Glucose Monitoring Improves Time in Target and HbA in a Multiethnic Cohort of Adolescents and Young Adults With Type 1 Diabetes: The MILLENNIALS Study. Diabetes Care. 2020; 43(10):2537-2543. DOI: 10.2337/dc20-0736. View

2.
Pease A, Zomer E, Liew D, Earnest A, Soldatos G, Ademi Z . Cost-Effectiveness Analysis of a Hybrid Closed-Loop System Versus Multiple Daily Injections and Capillary Glucose Testing for Adults with Type 1 Diabetes. Diabetes Technol Ther. 2020; 22(11):812-821. DOI: 10.1089/dia.2020.0064. View

3.
Hovorka R, Allen J, Elleri D, Chassin L, Harris J, Xing D . Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial. Lancet. 2010; 375(9716):743-51. DOI: 10.1016/S0140-6736(09)61998-X. View

4.
Andreozzi F, Candido R, Corrao S, Fornengo R, Giancaterini A, Ponzani P . Clinical inertia is the enemy of therapeutic success in the management of diabetes and its complications: a narrative literature review. Diabetol Metab Syndr. 2020; 12:52. PMC: 7301473. DOI: 10.1186/s13098-020-00559-7. View

5.
Schoelwer M, Sherr J, Weyman K, Tichy E, VanName M, Brei M . Safety and Glycemic Outcomes With a Tubeless Automated Insulin Delivery System in Very Young Children With Type 1 Diabetes: A Single-Arm Multicenter Clinical Trial. Diabetes Care. 2022; 45(8):1907-1910. PMC: 9346983. DOI: 10.2337/dc21-2359. View