Wireless Non-Invasive Monitoring of Cholesterol Using a Smart Contact Lens

Overview
Journal Adv Sci (Weinh)
Date 2022 Aug 17
PMID 35975449
Authors
Affiliations
Soon will be listed here.
Abstract

Herein, a wireless and soft smart contact lens that enables real-time quantitative recording of cholesterol in tear fluids for the monitoring of patients with hyperlipidemia using a smartphone is reported. This contact lens incorporates an electrochemical biosensor for the continuous detection of cholesterol concentrations, stretchable antenna, and integrated circuits for wireless communication, which makes a smartphone the only device required to operate this lens remotely without obstructing the wearer's vision. The hyperlipidemia rabbit model is utilized to confirm the correlation between cholesterol levels in tear fluid and blood and to confirm the feasibility of this smart contact lens for diagnostic application of cholesterol-related diseases. Further in vivo tests with human subjects demonstrated its good biocompatibility, wearability, and reliability as a non-invasive healthcare device.

Citing Articles

Smart Contact Lenses: Disease Monitoring and Treatment.

Pan M, Zhang Z, Shang L Research (Wash D C). 2025; 8:0611.

PMID: 39931295 PMC: 11808174. DOI: 10.34133/research.0611.


A bibliometric and visualization analysis of electrochemical biosensors for early diagnosis of eye diseases.

Zhang F, Xu W, Deng Z, Huang J Front Med (Lausanne). 2025; 11:1487981.

PMID: 39867928 PMC: 11757256. DOI: 10.3389/fmed.2024.1487981.


MOF-based spectrophotometric sensors for cholesterol detection: current trends and challenges.

Abed H, Sabouni R, Ghommem M RSC Adv. 2024; 14(53):39472-39497.

PMID: 39679417 PMC: 11641095. DOI: 10.1039/d4ra07476a.


Multimodal integrated flexible neural probe for monitoring of EEG and lactic acid.

Zhang L, Xia J, Li B, Cao Z, Dong S RSC Adv. 2024; 14(48):35520-35528.

PMID: 39507693 PMC: 11540061. DOI: 10.1039/d4ra06336h.


Tear-Based Ocular Wearable Biosensors for Human Health Monitoring.

Rajan A, Vishnu J, Shankar B Biosensors (Basel). 2024; 14(10).

PMID: 39451696 PMC: 11506517. DOI: 10.3390/bios14100483.


References
1.
Grundy S, Cleeman J, Merz C, Brewer Jr H, Clark L, Hunninghake D . Implications of recent clinical trials for the National Cholesterol Education Program Adult Treatment Panel III Guidelines. J Am Coll Cardiol. 2004; 44(3):720-32. DOI: 10.1016/j.jacc.2004.07.001. View

2.
Schwartz G, Tee B, Mei J, Appleton A, Kim D, Wang H . Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring. Nat Commun. 2013; 4:1859. DOI: 10.1038/ncomms2832. View

3.
Coskun V, Ozdenizci B, Ok K . The Survey on Near Field Communication. Sensors (Basel). 2015; 15(6):13348-405. PMC: 4507650. DOI: 10.3390/s150613348. View

4.
Kim J, Park J, Park Y, Cha E, Ku M, An H . A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure. Nat Biomed Eng. 2021; 5(7):772-782. DOI: 10.1038/s41551-021-00719-8. View

5.
Kim S, Lee G, Jeon C, Han H, Kim S, Mok J . Bimetallic Nanocatalysts Immobilized in Nanoporous Hydrogels for Long-Term Robust Continuous Glucose Monitoring of Smart Contact Lens. Adv Mater. 2022; 34(18):e2110536. PMC: 10782562. DOI: 10.1002/adma.202110536. View