» Articles » PMID: 35906313

Evaluation of the Use of Non-invasive Hemoglobin Measurement in Early Childhood

Overview
Journal Pediatr Res
Specialties Biology
Pediatrics
Date 2022 Jul 29
PMID 35906313
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Iron deficiency anemia in children affects psychomotor development. We compared the accuracy and trend of a non-invasive transcutaneous spectrophotometric estimation of arterial hemoglobin (Hb) concentration (SpHb) by rainbow pulse CO-oximetry technology to the invasive blood Hb concentration measured by an automated clinical analyzer (Hb-Lab).

Methods: We measured the SpHb and Hb-Lab in 109 patients aged 1-5 years. Regression analysis was used to evaluate differences between the two methods. The bias, accuracy, precision, and limits of agreement of SpHb compared with Hb-Lab were calculated using the Bland-Altman method.

Results: Of the 109 enrolled subjects, 102 pairs of the SpHb and Hb-Lab datasets were collected. The average value of measured Hb was 12.9 ± 1.03 (standard deviation [SD]) g/dL for Hb-Lab. A significant correlation was observed between SpHb and Hb-Lab measurements (SpHb = 7.002 + 0.4722 Hb-Lab, correlation coefficient r = 0.548, 95% confidence interval = 0.329-0.615). Bland-Altman analysis showed good visual agreement, with a mean bias between SpHb and Hb-Lab of 0.188 ± 0.919 g/dL (mean ± SD).

Conclusions: We concluded that non-invasive Hb measurement is useful for Hb estimation in children and provides new insights as a screening tool for anemia.

Impact: Our results indicated a good correlation between non-invasive transcutaneous spectrophotometric estimation of arterial hemoglobin (Hb) concentration using a finger probe sensor by rainbow pulse CO-oximetry technology and invasive blood Hb concentration. Although previous studies have indicated that in patients with a worse condition, the bias between the two methods was large, this study, which was conducted on children with stable disease, showed a relatively small bias. Further studies using this non-invasive device might help to understand the current status of anemia in Japan and promote iron intake and nutritional management in children.

Citing Articles

Evaluation of Non-Invasive Hemoglobin Monitoring in Perioperative Patients: A Retrospective Study of the Rad-67 (Masimo).

Helmer P, Steinisch A, Hottenrott S, Schlesinger T, Sammeth M, Meybohm P Diagnostics (Basel). 2025; 15(2).

PMID: 39857014 PMC: 11763668. DOI: 10.3390/diagnostics15020128.


Accuracy of noninvasive total haemoglobin measurement for detecting anaemia in infants: a cross-sectional study in a well-child care clinic, Khon Kaen, Thailand.

Saengnipanthkul S, Tawiangnan C, Sirikarn P, Supasai S, Sitthikarnkha P, Techasatian L BMJ Open. 2025; 14(12):e083356.

PMID: 39806708 PMC: 11749846. DOI: 10.1136/bmjopen-2023-083356.


Comparison of a non-invasive point-of-care measurement of anemia to conventionally used HemoCue devices in Gambella refugee camp, Ethiopia, 2022.

Smith F, Woldeyohannes M, Lusigi M, Samson K, Mureverwi B, Gazarwa D PLoS One. 2025; 20(1):e0313319.

PMID: 39804917 PMC: 11729968. DOI: 10.1371/journal.pone.0313319.


Non-invasive hemoglobin measurement using optical method.

R R, S P, A S K, J B J Heliyon. 2024; 10(15):e35777.

PMID: 39170470 PMC: 11337058. DOI: 10.1016/j.heliyon.2024.e35777.


Real-time non-invasive hemoglobin prediction using deep learning-enabled smartphone imaging.

Chen Y, Hu X, Zhu Y, Liu X, Yi B BMC Med Inform Decis Mak. 2024; 24(1):187.

PMID: 38951831 PMC: 11218390. DOI: 10.1186/s12911-024-02585-1.


References
1.
Kassebaum N, Jasrasaria R, Naghavi M, Wulf S, Johns N, Lozano R . A systematic analysis of global anemia burden from 1990 to 2010. Blood. 2013; 123(5):615-24. PMC: 3907750. DOI: 10.1182/blood-2013-06-508325. View

2.
Baker R, Greer F . Diagnosis and prevention of iron deficiency and iron-deficiency anemia in infants and young children (0-3 years of age). Pediatrics. 2010; 126(5):1040-50. DOI: 10.1542/peds.2010-2576. View

3.
Athe R, Vishnu Vardhana Rao M, Nair K . Impact of iron-fortified foods on Hb concentration in children (<10 years): a systematic review and meta-analysis of randomized controlled trials. Public Health Nutr. 2013; 17(3):579-86. PMC: 10282399. DOI: 10.1017/S1368980013000062. View

4.
Lukowski A, Koss M, Burden M, Jonides J, Nelson C, Kaciroti N . Iron deficiency in infancy and neurocognitive functioning at 19 years: evidence of long-term deficits in executive function and recognition memory. Nutr Neurosci. 2010; 13(2):54-70. PMC: 3151652. DOI: 10.1179/147683010X12611460763689. View

5.
Morris S, Ruel M, Cohen R, Dewey K, de la Briere B, Hassan M . Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood. Am J Clin Nutr. 1999; 69(6):1243-8. DOI: 10.1093/ajcn/69.6.1243. View