» Articles » PMID: 35801815

Short-term Tear Film Stability, Optical Quality and Visual Performance in Two Dual-focus Contact Lenses for Myopia Control with Different Optical Designs

Overview
Date 2022 Jul 8
PMID 35801815
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To assess and compare short-term visual and optical quality and tear film stability between two dual-focus (DF) prototype myopia control contact lenses (CLs) having different inner zone diameters.

Methods: Twenty-eight myopic subjects were included in this randomised, double-masked crossover study. Refraction, best-corrected visual acuity (VA) and tear film stability were measured at baseline (i.e., when uncorrected). Subjects were then binocularly fitted with the DF CLs, with only the sensorial dominant eye being assessed. Lenses were of the same material and had inner zone diameters of either 2.1 mm (S design) or 4.0 mm (M design). Visual and physical short-term lens comfort, over-refraction, best-corrected VA, stereopsis at 40 cm, best-corrected photopic and mesopic contrast sensitivity (CS), size and shape of light disturbance (LD), wavefront aberrations, subjective quality of vision (QoV Questionnaire) and tear film stability were measured for each lens.

Results: Both CL designs decreased tear film stability compared with baseline (p < 0.05). VA and photopic CS were within normal values for the subjects' age with each CL. When comparing lenses, the M design promoted better photopic CS for the 18 cycles per degree spatial frequency (p < 0.001) and better LD (p < 0.02). However, higher-order aberrations were improved with the S design (p = 0.02). No significant difference between the two CLs was found for QoV scores and tear film stability.

Conclusions: Both DF CLs provided acceptable visual performance under photopic conditions. The 4.0 mm inner zone gave better contrast sensitivity at high frequencies and lower light disturbance, while the 2.1 mm central diameter induced fewer higher-order aberrations for a 5 mm pupil diameter. Both CLs produced the same subjective visual short-term lens comfort.

Citing Articles

Research Tendency and Frontiers of Multifocal Lenses in Myopic Control in the Past Two Decades: A Bibliometric Analysis.

Jiang L, Yu M, Cai J, Wang Y, Hu H, Chen M Healthcare (Basel). 2025; 13(2).

PMID: 39857231 PMC: 11764832. DOI: 10.3390/healthcare13020204.


Statistical Model of Ocular Wavefronts With Accommodation.

Mecho-Garcia M, Arcas-Carbonell M, Orduna-Hospital E, Sanchez-Cano A, Lopez-Gil N, Macedo-de-Araujo R Invest Ophthalmol Vis Sci. 2024; 65(12):12.

PMID: 39377736 PMC: 11463707. DOI: 10.1167/iovs.65.12.12.


Impact of wearing dual-focus soft contact lenses on myopia progression: a one-year randomized clinical trial in Chinese school-age children.

Chen Y, Yang B, Kou J, Liu L BMC Ophthalmol. 2024; 24(1):426.

PMID: 39350093 PMC: 11443923. DOI: 10.1186/s12886-024-03678-1.


Daytime Changes in Tear Film Parameters and Visual Acuity with New-Generation Daily Disposable Silicone Hydrogel Contact Lenses-A Double-Masked Study in Symptomatic Subjects.

Macedo-de-Araujo R, Rico-Del-Viejo L, Martin-Montanez V, Queiros A, Gonzalez-Meijome J Vision (Basel). 2024; 8(1).

PMID: 38535760 PMC: 10975303. DOI: 10.3390/vision8010011.


Exploring the Cutting Edge of Vision Science: New Developments in Diagnostics and Treatment of Ocular Surface in Dry Eye Disease.

Sanchez-Gonzalez J, Rocha-de-Lossada C, Cervino A Life (Basel). 2023; 13(7).

PMID: 37511959 PMC: 10381868. DOI: 10.3390/life13071584.


References
1.
Garcia-Lazaro S, Ferrer-Blasco T, Madrid-Costa D, Albarran-Diego C, Montes-Mico R . Visual performance of four simultaneous-image multifocal contact lenses under dim and glare conditions. Eye Contact Lens. 2014; 41(1):19-24. DOI: 10.1097/ICL.0000000000000060. View

2.
Escandon-Garcia S, Ribeiro F, McAlinden C, Queiros A, Gonzalez-Meijome J . Through-Focus Vision Performance and Light Disturbances of 3 New Intraocular Lenses for Presbyopia Correction. J Ophthalmol. 2018; 2018:6165493. PMC: 5831879. DOI: 10.1155/2018/6165493. View

3.
Hughes R, Vincent S, Read S, Collins M . Higher order aberrations, refractive error development and myopia control: a review. Clin Exp Optom. 2019; 103(1):68-85. DOI: 10.1111/cxo.12960. View

4.
Faria-Ribeiro M, Amorim-de-Sousa A, Gonzalez-Meijome J . Predicted accommodative response from image quality in young eyes fitted with different dual-focus designs. Ophthalmic Physiol Opt. 2018; 38(3):309-316. DOI: 10.1111/opo.12443. View

5.
Gonzalez-Meijome J, Peixoto-de-Matos S, Faria-Ribeiro M, Lopes-Ferreira D, Jorge J, Legerton J . Strategies to Regulate Myopia Progression With Contact Lenses: A Review. Eye Contact Lens. 2015; 42(1):24-34. DOI: 10.1097/ICL.0000000000000100. View