CGM in the Hospital: Is It Ready for Prime Time?

Overview
Journal Curr Diab Rep
Publisher Current Science
Specialty Endocrinology
Date 2022 Jul 7
PMID 35796882
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose Of Review: The use of continuous glucose monitoring (CGM) in the hospital setting is growing with more patients using these devices at home and when admitted to the hospital, especially during the COVID-19 pandemic.

Recent Findings: Historically, most evidence for CGM use in the inpatient setting was limited to small studies utilizing outdated CGM technology and analyzing accuracy of sensor measurements. Previous studies have shown reduced sensor accuracy during extreme hypo- or hyperglycemia, rapid fluctuations of glucose, compression of the sensor itself, and in those who are critically ill. Studies that are more recent have shown CGM to have adequate accuracy and may be effective in reducing hypoglycemia in hospitalized patients; some studies have also showed improvement in time in target glycemic range. Furthermore, CGM may reduce nursing workload, cost of inpatient care, and use of personal protective equipment and face-to-face patient care especially for patients during the COVID-19 pandemic. This review will describe the evidence for use of CGM in hospitalized critically ill or non-critically ill patients, address accuracy and safety considerations, and outline paths for future implementation.

Citing Articles

Investigation of Glucose Metabolism by Continuous Glucose Monitoring and Validation of Dipeptidyl Peptidase 4 Inhibitor Use in Patients with Myotonic Dystrophy Type 1.

Takada H, Matsumura T, Shimamura H, Matsui M, Kon S, Fukumoto A J Clin Med. 2024; 13(17).

PMID: 39274465 PMC: 11396113. DOI: 10.3390/jcm13175252.


Continuous Insulin Therapy to Prevent Post-Transplant Diabetes Mellitus: A Randomized Controlled Trial.

Kurnikowski A, Werzowa J, Hodlmoser S, Krenn S, Paschen C, Mussnig S Kidney Med. 2024; 6(8):100860.

PMID: 39157193 PMC: 11326904. DOI: 10.1016/j.xkme.2024.100860.


Accuracy of continuous glucose monitoring in the hospital setting: an observational study.

OConnor M, Flint K, Sabean A, Ashley A, Zheng H, Yan J Diabetologia. 2024; 67(12):2650-2659.

PMID: 39126488 DOI: 10.1007/s00125-024-06250-0.


Summary of clinical investigation plan for The DIATEC trial: in-hospital diabetes management by a diabetes team and continuous glucose monitoring or point of care glucose testing - a randomised controlled trial.

Olsen M, Klarskov C, Pedersen-Bjergaard U, Hansen K, Kristensen P BMC Endocr Disord. 2024; 24(1):60.

PMID: 38711112 PMC: 11071255. DOI: 10.1186/s12902-024-01595-4.


Accuracy of a Real-Time Continuous Glucose Monitor in Pediatric Diabetic Ketoacidosis Admissions.

Waterman L, Pyle L, Forlenza G, Towers L, Karami A, Jost E Diabetes Technol Ther. 2024; 26(9):626-632.

PMID: 38441904 PMC: 11535449. DOI: 10.1089/dia.2023.0542.