» Articles » PMID: 35352440

Interleaved and Simultaneous Multi-nuclear Magnetic Resonance in Vivo. Review of Principles, Applications and Potential

Overview
Journal NMR Biomed
Publisher Wiley
Date 2022 Mar 30
PMID 35352440
Authors
Affiliations
Soon will be listed here.
Abstract

Magnetic resonance signals from different nuclei can be excited or received at the same time,rendering simultaneous or rapidly interleaved multi-nuclear acquisitions feasible. The advan-tages are a reduction of total scan time compared to sequential multi-nuclear acquisitions or that additional information from heteronuclear data is obtained at thesame time and anatomical position. Information content can be qualitatively increased by delivering a more comprehensive MR-based picture of a transient state (such as an exercise bout). Also, combiningnon-proton MR acquisitions with Hinformation (e.g., dynamic shim updates and motion correction) can be used to improve data quality during long scans and benefits image coregistration. This work reviews the literature on interleaved and simultaneous multi-nuclear MRI and MRS in vivo. Prominent use cases for this methodology in clinical and research applications are brain and muscle, but studies have also been carried out in other targets, including the lung, knee, breast and heart. Simultaneous multi-nuclear measurements in the liver and kidney have also been performed, but exclusively in rodents. In this review, a consistent nomenclature is proposed, to help clarify the terminology used for this principle throughout the literature on in-vivo MR. An overview covers the basic principles, the technical requirements on the MR scanner and the implementations realised either by MR system vendors or research groups, from the early days until today. Considerations regarding the multi-tuned RF coils required and heteronuclear polarisation interactions are briefly discussed, and fields for future in-vivo applications for interleaved multi-nuclear MR pulse sequences are identified.

Citing Articles

Interleaved Whole Brain Na-MRI and P-MRSI Acquisitions at 7 Tesla.

Shams Z, Dai J, Gosselink M, Hoogduin H, van der Kemp W, Visser F NMR Biomed. 2025; 38(3):e70012.

PMID: 39956139 PMC: 11830465. DOI: 10.1002/nbm.70012.


Multinuclear Interleaving of H CEST, Water T*, and Na MRI at 3 T.

Lopez Kolkovsky A, Wang C, Yao J, Ellingson B NMR Biomed. 2025; 38(3):e70003.

PMID: 39948226 PMC: 11825412. DOI: 10.1002/nbm.70003.


Lactate and lactylation in cancer.

Chen J, Huang Z, Chen Y, Tian H, Chai P, Shen Y Signal Transduct Target Ther. 2025; 10(1):38.

PMID: 39934144 PMC: 11814237. DOI: 10.1038/s41392-024-02082-x.


Development of a Double Tuned H/P Whole-Body Birdcage Transmit Coil for H and P MR Applications From Head to Toe at 7 T.

Gursan A, Kahraman-Agir B, Gosselink M, Welting D, Froeling M, Hoogduin H NMR Biomed. 2025; 38(3):e5325.

PMID: 39888087 PMC: 11783138. DOI: 10.1002/nbm.5325.


A modular motion compensation pipeline for prospective respiratory motion correction of multi-nuclear MR spectroscopy.

Wampl S, Korner T, Meyerspeer M, Zaitsev M, Wolf M, Trattnig S Sci Rep. 2024; 14(1):10781.

PMID: 38734781 PMC: 11088657. DOI: 10.1038/s41598-024-61403-w.


References
1.
Reyngoudt H, Turk S, Carlier P . H NMRS of carnosine combined with P NMRS to better characterize skeletal muscle pH dysregulation in Duchenne muscular dystrophy. NMR Biomed. 2017; 31(1). DOI: 10.1002/nbm.3839. View

2.
Pipe J . Reconstructing MR images from undersampled data: data-weighting considerations. Magn Reson Med. 2000; 43(6):867-75. DOI: 10.1002/1522-2594(200006)43:6<867::aid-mrm13>3.0.co;2-2. View

3.
Lebon V, Brillault-Salvat C, Bloch G, Leroy-Willig A, Carlier P . Evidence of muscle BOLD effect revealed by simultaneous interleaved gradient-echo NMRI and myoglobin NMRS during leg ischemia. Magn Reson Med. 1998; 40(4):551-8. DOI: 10.1002/mrm.1910400408. View

4.
Chance B, Eleff S, Leigh Jr J . Noninvasive, nondestructive approaches to cell bioenergetics. Proc Natl Acad Sci U S A. 1980; 77(12):7430-4. PMC: 350517. DOI: 10.1073/pnas.77.12.7430. View

5.
Price T, Laurent D, Petersen K, Rothman D, Shulman G . Glycogen loading alters muscle glycogen resynthesis after exercise. J Appl Physiol (1985). 2000; 88(2):698-704. DOI: 10.1152/jappl.2000.88.2.698. View