An Integrated Pulsation-Free, Backflow-Free Micropump Using the Analog Waveform-Driven Braille Actuator

Overview
Publisher MDPI
Date 2022 Feb 25
PMID 35208418
Authors
Affiliations
Soon will be listed here.
Abstract

The widespread adoption of long-term organs-on-a-chip culture necessitates both active perfusions that mimic physiological flow conditions and minimization of the complexity of microfluidic system and fluid handling. In particular, flow in microtissue such as microvascular is free of pulsation and backflow. The refreshable Braille actuator-based integrated microfluidic system can be employed with simple microchannels and setups. However, due to high pulsatile flow and backflow, ordinary Braille-driven micropumps generate non-physiological flow conditions. We have described a simple method for creating steady flow employing Braille actuators driven with a high-voltage analog waveform, called "constant flow waveform", without incorporating complicated structures into the microchannel or actuator. We determined the constant flow waveform by measuring volume change of microchannel caused by actuated Braille pins using a conventional fluorescent dye and microscope. Using the constant flow waveform, we demonstrated that a Braille-driven pump reduced pulsating flow by 79% and backflow by 63% compared to conventional Braille-driven pump. Furthermore, we demonstrated that a parallel pair of three-stranded pin pumps effectively eliminated backflow by driving two pumps with the constant flow waveform half-cycle shifted to each other. Moreover, by raising the driving frequency, we could increase the average flow rate to ~2× higher than previously reported flow rate of a typical Braille-driven micropump.

Citing Articles

In Vitro Model of Vascular Remodeling Under Microfluidic Perfusion.

Nishikata K, Doi K, Kaneoya N, Nakamura M, Futai N Micromachines (Basel). 2025; 16(1).

PMID: 39858670 PMC: 11767722. DOI: 10.3390/mi16010014.


Pulsation Reduction Using Dual Sidewall-Driven Micropumps.

Atsumi T, Takayama T, Kaneko M Micromachines (Basel). 2023; 14(1).

PMID: 36677080 PMC: 9863840. DOI: 10.3390/mi14010019.

References
1.
Lee J, Estlack Z, Somaweera H, Wang X, Lacerda C, Kim J . A microfluidic cardiac flow profile generator for studying the effect of shear stress on valvular endothelial cells. Lab Chip. 2018; 18(19):2946-2954. DOI: 10.1039/c8lc00545a. View

2.
Hsu Y, L Moya M, Abiri P, Hughes C, George S, Lee A . Full range physiological mass transport control in 3D tissue cultures. Lab Chip. 2012; 13(1):81-9. PMC: 3510322. DOI: 10.1039/c2lc40787f. View

3.
Park S, Georgescu A, Huh D . Organoids-on-a-chip. Science. 2019; 364(6444):960-965. PMC: 7764943. DOI: 10.1126/science.aaw7894. View

4.
Futai N, Gu W, Song J, Takayama S . Handheld recirculation system and customized media for microfluidic cell culture. Lab Chip. 2005; 6(1):149-54. DOI: 10.1039/b510901a. View

5.
Yin L, Du G, Zhang B, Zhang H, Yin R, Zhang W . Efficient Drug Screening and Nephrotoxicity Assessment on Co-culture Microfluidic Kidney Chip. Sci Rep. 2020; 10(1):6568. PMC: 7162892. DOI: 10.1038/s41598-020-63096-3. View