Perfusion Measurement in Brain Gliomas Using Velocity-selective Arterial Spin Labeling: Comparison with Pseudo-continuous Arterial Spin Labeling and Dynamic Susceptibility Contrast MRI
Overview
Authors
Affiliations
Objectives: To evaluate the performance of velocity-selective (VS) ASL among patients with untreated gliomas by comparing with both pseudo-continuous (PC) ASL and dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI).
Methods: Forty-four consecutive patients with newly diagnosed glioma who underwent preoperative perfusion MRI including VSASL, PCASL, and DSC-PWI between 2017 and 2019 were retrospectively evaluated. Visual inspection was performed to evaluate the tumor signal intensity relative to gray matter based on 1-5 score criteria and weighted kappa was used to evaluate the pair-wise concordance between VSASL or PCASL and DSC-PWI. The relative tumor blood flow (rTBF) was measured from sampling intra-tumoral areas of hot-spot on the blood flow map and normalized against the contralateral normal gray matter blood flow. Linear regression and Bland-Altman analyses were performed to evaluate the correlation and agreement of rTBF measurements between ASL methods and DSC-PWI. The ROC analysis was constructed to determine the diagnostic performance of three perfusion methods for grading gliomas.
Results: TBF maps derived from VSASL were more comparable with DSC-PWI than PCASL on visual inspection (weighted kappa of 0.90 vs 0.68). In quantitative analysis, VSASL-rTBF yielded higher correlation with the values from DSC-PWI than PCASL-rTBF (R = 80% vs 47%, p < 0.001 for both). Both ASL and DSC-derived rTBF showed good distinction between low-grade and high-grade gliomas (p < 0.001). Compared to PCASL, VSASL yielded superior diagnostic sensitivity, specificity, and accuracy in glioma grading.
Conclusions: VSASL showed great promise for accurate quantification of TBF and could potentially improve the diagnostic performance of ASL in preoperative grading of gliomas.
Key Points: • VSASL demonstrated a greater agreement with DSC-PWI than with PCASL on visual inspection and perfusion quantification. • VSASL showed a higher diagnostic sensitivity, negative predictive value, and accuracy than PCASL for glioma grading. • With the advantages of insensitivity to transit delay and no need of prescribing a labeling plane, VSASL could potentially improve the diagnostic performance of ASL for a more accurate, noninvasive quantification of TBF in patients with glioma.
Azizova A, Prysiazhniuk Y, Wamelink I, Cakmak M, Kaya E, Wesseling P Eur Radiol. 2024; 35(3):1242-1254.
PMID: 39425768 PMC: 11836213. DOI: 10.1007/s00330-024-11140-5.
Liu D, Zhu D, Qin Q Magn Reson Med. 2024; 92(2):761-771.
PMID: 38523590 PMC: 11142876. DOI: 10.1002/mrm.30085.
Bayraktar E, Duygulu G, Cetinoglu Y, Gelal M, Apaydin M, Ellidokuz H BMC Med Imaging. 2024; 24(1):70.
PMID: 38519901 PMC: 10958956. DOI: 10.1186/s12880-024-01249-w.
Lambrecht S, Liu D, Dzaye O, Kamson D, Reis J, Liebig T Brain Sci. 2024; 14(2).
PMID: 38391701 PMC: 10886779. DOI: 10.3390/brainsci14020126.
Brain Tumor Imaging without Gadolinium-based Contrast Agents: Feasible or Fantasy?.
Wamelink I, Azizova A, Booth T, Mutsaerts H, Ogunleye A, Mankad K Radiology. 2024; 310(2):e230793.
PMID: 38319162 PMC: 10902600. DOI: 10.1148/radiol.230793.