» Articles » PMID: 19365865

Can Arterial Spin Labeling Detect White Matter Perfusion Signal?

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2009 Apr 15
PMID 19365865
Citations 117
Authors
Affiliations
Soon will be listed here.
Abstract

Since the invention of arterial spin labeling (ASL) it has been acknowledged that ASL does not allow reliable detection of a white matter (WM) perfusion signal. However, recent developments such as pseudo-continuous labeling and background suppression have improved the quality. The goal of this research was to study the ability of these newer ASL sequences to detect WM perfusion signal. Background suppressed pseudo-continuous ASL was implemented at 3T with multislice 2D readout after 1525 ms. In five volunteers it was shown that 10 min scanning resulted in significant perfusion signal in 70% of WM voxels. Increasing the labeling and delay time did not lead to a higher percentage. In 27 normal volunteers it was found that 35 averages are necessary to detect significant WM signal, but 150 averages are needed to detect signal in the deep WM. Finally, it was shown in a patient with a cerebral arteriovenous malformation that pseudo-continuous ASL enabled the depiction of hypointense WM perfusion signal, although dynamic susceptibility contrast MRI showed that this region was merely showing delayed arrival of contrast agent than hypoperfusion. It can be concluded that, except within the deep WM, ASL is sensitive enough to detect WM perfusion signal and perfusion deficits.

Citing Articles

Detectability of white matter cerebral blood flow using arterial spin labeling MRI in patients with sickle cell disease: Relevance of flow territory, bolus arrival time and hematocrit.

Richerson W, Aumann M, Song A, Eisma J, Davis S, Milner L J Cereb Blood Flow Metab. 2024; 45(3):486-497.

PMID: 39253827 PMC: 11572042. DOI: 10.1177/0271678X241270283.


Improved MRI methods to quantify retinal and choroidal blood flow applied to a model of glaucoma.

Jiang Z, Chernoff D, Galenchik-Chan A, Tomorri D, Honkanen R, Duong T Front Ophthalmol (Lausanne). 2024; 4:1385495.

PMID: 38984144 PMC: 11182105. DOI: 10.3389/fopht.2024.1385495.


Simultaneous assessment of blood flow and myelin content in the brain white matter with dynamic [11 C]PiB PET: a test-retest study in healthy controls.

Yazdan-Panah A, Bodini B, Soulier T, Veronese M, Bottlaender M, Tonietto M EJNMMI Res. 2024; 14(1):50.

PMID: 38801594 PMC: 11130116. DOI: 10.1186/s13550-024-01107-4.


Recommendations for quantitative cerebral perfusion MRI using multi-timepoint arterial spin labeling: Acquisition, quantification, and clinical applications.

Woods J, Achten E, Asllani I, Bolar D, Dai W, Detre J Magn Reson Med. 2024; 92(2):469-495.

PMID: 38594906 PMC: 11142882. DOI: 10.1002/mrm.30091.


Macro- and microvascular contributions to cerebral structural alterations in patients with asymptomatic carotid artery stenosis.

Schmitzer L, Kaczmarz S, Gottler J, Hoffmann G, Kallmayer M, Eckstein H J Cereb Blood Flow Metab. 2024; 44(9):1629-1642.

PMID: 38506325 PMC: 11418673. DOI: 10.1177/0271678X241238935.