» Articles » PMID: 35053655

Can Fraction of Inspired Oxygen Predict Extubation Failure in Preterm Infants?

Abstract

Background: Prolonged mechanical ventilation in preterm infants may cause complications. We aimed to analyze the variables affecting extubation outcomes in preterm infants at high risk of extubation failure.

Methods: This was a single-center, observational, retrospective study. Extubation failure was defined as survival with the need for reintubation within 72 h. Successfully extubated neonates (group 1) were compared to those with failed extubation (group 2). Multivariate logistic regression analysis evaluated factors that predicted extubation outcomes.

Results: Eighty infants with a birth weight under 1000 g and/or gestational age (GA) under 28 weeks were included. Extubation failure occurred in 29 (36.2%) and success in 51 (63.8%) neonates. Most failures (75.9%) occurred within 24 h. Pre-extubation inspired oxygen fraction (FiO) of 27% had a sensitivity of 58.6% and specificity of 64.7% for extubation failure. Post-extubation FiO of 32% had a sensitivity of 65.5% and specificity of 62.8% for failure. Prolonged membrane rupture (PROM) and high GA were associated with extubation success in multivariate logistic regression analysis.

Conclusions: High GA and PROM were associated with extubation success. Pre- and post-extubation FiO values were not significantly predictive of extubation failure. Further studies should evaluate if overall assessment, including ventilatory parameters and clinical factors, can predict extubation success in neonates.

Citing Articles

Predicting extubation failure in neonates: The role of lung ultrasound and corrected gestational age in safe weaning in the NICU.

Rojas B, Procianoy R, de Souza A, Rigodanzo C, Trindade G, Furlan S Eur J Pediatr. 2025; 184(2):144.

PMID: 39825155 DOI: 10.1007/s00431-025-05977-1.


Predictors of extubation failure in newborns: a systematic review and meta-analysis.

Fu M, Hu Z, Yu G, Luo Y, Xiong X, Yang Q Ital J Pediatr. 2023; 49(1):133.

PMID: 37784184 PMC: 10546653. DOI: 10.1186/s13052-023-01538-0.


Feasibility of Endotracheal Extubation Evaluation Form in Predicting Successful Extubation in Neonatal Intensive Care Units: A Retrospective Study.

Liu Y, Yeh C, Yang S, Chung W, Hsu T, Sheu C Children (Basel). 2023; 10(6).

PMID: 37371284 PMC: 10297584. DOI: 10.3390/children10061053.

References
1.
Kattwinkel J, Perlman J, Aziz K, Colby C, Fairchild K, Gallagher J . Part 15: neonatal resuscitation: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2010; 122(18 Suppl 3):S909-19. DOI: 10.1161/CIRCULATIONAHA.110.971119. View

2.
SantAnna G, Keszler M . Weaning infants from mechanical ventilation. Clin Perinatol. 2012; 39(3):543-62. DOI: 10.1016/j.clp.2012.06.003. View

3.
Gillespie L, White S, Sinha S, Donn S . Usefulness of the minute ventilation test in predicting successful extubation in newborn infants: a randomized controlled trial. J Perinatol. 2003; 23(3):205-7. DOI: 10.1038/sj.jp.7210886. View

4.
da Silva O, Stevens D . Complications of airway management in very-low-birth-weight infants. Biol Neonate. 1998; 75(1):40-5. DOI: 10.1159/000014075. View

5.
Garcia-De la Torre J, Delgado-Rosas A, Gonzelez-Cantu G . [Histologic chorioamnionitis prevalence in patients with premature rupture membranes]. Ginecol Obstet Mex. 2015; 82(12):791-5. View