» Articles » PMID: 34895722

Mortality Following Durable Left Ventricular Assist Device Implantation by Timing and Type of First Infection

Abstract

Objective: Although infections are common after left ventricular assist device implantation, the relationship between timing and type of first infection with regard to mortality is less well understood.

Methods: The Society of Thoracic Surgeons Interagency Registry for Mechanically Assisted Circulatory Support patients receiving a primary left ventricular assist device from April 2012 to May 2017 were included. The primary exposure was defined 3 ways: any infection, timing of first infection (early: ≤90 days; intermediate: 91-180 days; late: >180 days), and type (ventricular assist device specific, ventricular assist device related, non-ventricular assist device). The association between first infection and all-cause mortality was estimated using Cox regression.

Results: The cohort included 12,957 patients at 166 centers (destination therapy: 47.4%, bridge-to-transplant: 41.2%). First infections were most often non-ventricular assist device (54.2%). Rates of first infection were highest in the early interval (10.7/100 person-months). Patients with any infection had a significantly higher adjusted hazard of death (hazard ratio, 2.63; 2.46-2.86). First infection in the intermediate interval was associated with the largest increase in adjusted hazard of death (hazard ratio, 3.26; 2.82-3.78), followed by late (hazard ratio, 3.13; 2.77-3.53) and early intervals (hazard ratio, 2.37; 2.16-2.60). Ventricular assist device-related infections were associated with the largest increase in hazard of death (hazard ratio, 3.02; 2.69-3.40), followed by ventricular assist device specific (hazard ratio, 2.92; 2.57-3.32) and non-ventricular assist device (hazard ratio, 2.42; 2.20-2.65).

Conclusions: Relative to those without infection, patients with any postimplantation infection had an increased risk of death. Ventricular assist device-related infections and infections occurring in the intermediate interval were associated with the largest increase in risk of death. After left ventricular assist device implantation, infection prevention strategies should target non-ventricular assist device infections in the first 90 days, then shift to surveillance/prevention of driveline infections after 90 days.

Citing Articles

Interplay between driveline infection, vessel wall inflammation, cerebrovascular events and mortality in patients with left ventricular assist device.

Hupe J, Worthmann H, Ravenberg K, Grosse G, Ernst J, Haverich A Sci Rep. 2023; 13(1):18552.

PMID: 37899422 PMC: 10613624. DOI: 10.1038/s41598-023-45110-6.


Hemoadsorption in LVAD Surgery: Suitable in Theory?.

Ozturk M, Popov A J Cardiovasc Dev Dis. 2023; 10(7).

PMID: 37504542 PMC: 10380647. DOI: 10.3390/jcdd10070286.


Infections following left ventricular assist device implantation and 1-year health-related quality of life.

Zhou S, Yang G, Hou H, Zhang M, Grady K, Chenoweth C J Heart Lung Transplant. 2023; 42(9):1307-1315.

PMID: 37187319 PMC: 10527882. DOI: 10.1016/j.healun.2023.05.006.


Zwitterionic coating assisted by dopamine with metal-phenolic networks loaded on titanium with improved biocompatibility and antibacterial property for artificial heart.

Meng L, Huang C, Liu X, Qu H, Wang Q Front Bioeng Biotechnol. 2023; 11:1167340.

PMID: 37139045 PMC: 10150318. DOI: 10.3389/fbioe.2023.1167340.

References
1.
Chandanabhumma P, Fetters M, Pagani F, Malani P, Hollingsworth J, Funk R . Understanding and Addressing Variation in Health Care-Associated Infections After Durable Ventricular Assist Device Therapy: Protocol for a Mixed Methods Study. JMIR Res Protoc. 2020; 9(1):e14701. PMC: 6996720. DOI: 10.2196/14701. View

2.
Patel C, Blue L, Cagliostro B, Bailey S, Entwistle J, John R . Left ventricular assist systems and infection-related outcomes: A comprehensive analysis of the MOMENTUM 3 trial. J Heart Lung Transplant. 2020; 39(8):774-781. DOI: 10.1016/j.healun.2020.03.002. View

3.
Frontera J, Starling R, Cho S, Nowacki A, Uchino K, Hussain M . Risk factors, mortality, and timing of ischemic and hemorrhagic stroke with left ventricular assist devices. J Heart Lung Transplant. 2017; 36(6):673-683. DOI: 10.1016/j.healun.2016.12.010. View

4.
Holman W, Kirklin J, Naftel D, Kormos R, Desvign-Nickens P, Camacho M . Infection after implantation of pulsatile mechanical circulatory support devices. J Thorac Cardiovasc Surg. 2010; 139(6):1632-1636.e2. DOI: 10.1016/j.jtcvs.2010.01.014. View

5.
Gordon S, Schmitt S, Jacobs M, Smedira N, Goormastic M, Banbury M . Nosocomial bloodstream infections in patients with implantable left ventricular assist devices. Ann Thorac Surg. 2001; 72(3):725-30. DOI: 10.1016/s0003-4975(01)02888-0. View