» Articles » PMID: 34356704

Development of a Lateral Flow Immunoassay (LFIA) to Screen for the Release of the Endocrine Disruptor Bisphenol A from Polymer Materials and Products

Overview
Specialty Biotechnology
Date 2021 Aug 6
PMID 34356704
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

One of the most important chemicals used in the production of polymer plastics and coatings is bisphenol A. However, despite the large number of studies on the toxicity and hormonal activity of BPA, there are still open questions and thus considerable media attention regarding BPA toxicity. Hence, it is necessary to develop a sensitive, simple, cost-efficient, specific, portable, and rapid method for monitoring bisphenol A and for high sample throughput and on-site screening analysis. Lateral flow immunoassays have potential as rapid tests for on-site screening. To meet sensitivity criteria, they must be carefully optimized. A latex microparticle-based LFIA for detection of BPA was developed. The sensitivity of the assay was improved by non-contact printing of spot grids as the control and test lines with careful parameter optimization. Results of the test could be visually evaluated within 10 min with a visual cut-off of 10 µg/L (vLOD). Alternatively, photographs were taken, and image analysis performed to set up a calibration, which allowed for a calculated limit of detection (cLOD) of 0.14 µg/L. The method was validated for thermal paper samples against ELISA and LC-MS/MS as reference methods, showing good agreement with both methods.

Citing Articles

Re-assessment of monoclonal antibodies against diclofenac for their application in the analysis of environmental waters.

Schmidt S, Hoffmann H, Garbe L, Harrer A, Steiner M, Himly M Anal Methods. 2024; 16(21):3349-3363.

PMID: 38742423 PMC: 11138808. DOI: 10.1039/d3ay01333b.


An Overview to Molecularly Imprinted Electrochemical Sensors for the Detection of Bisphenol A.

Pan Y, Wu M, Shi M, Shi P, Zhao N, Zhu Y Sensors (Basel). 2023; 23(20).

PMID: 37896749 PMC: 10611091. DOI: 10.3390/s23208656.


BPA Endocrine Disruptor Detection at the Cutting Edge: FPIA and ELISA Immunoassays.

Raysyan A, Zwigart S, Eremin S, Schneider R Biosensors (Basel). 2023; 13(6).

PMID: 37367029 PMC: 10296492. DOI: 10.3390/bios13060664.


Latest Trends in Lateral Flow Immunoassay (LFIA) Detection Labels and Conjugation Process.

Mirica A, Stan D, Chelcea I, Mihailescu C, Ofiteru A, Bocancia-Mateescu L Front Bioeng Biotechnol. 2022; 10:922772.

PMID: 35774059 PMC: 9237331. DOI: 10.3389/fbioe.2022.922772.


Colloidal silver-based lateral flow immunoassay for detection of profenofos pesticide residue in vegetables.

Wu K, Huang W, Chang S, Shyu R RSC Adv. 2022; 12(21):13035-13044.

PMID: 35497005 PMC: 9052933. DOI: 10.1039/d2ra01654k.

References
1.
Nguyen V, Song S, Park S, Joo C . Recent advances in high-sensitivity detection methods for paper-based lateral-flow assay. Biosens Bioelectron. 2020; 152:112015. DOI: 10.1016/j.bios.2020.112015. View

2.
Russo G, Barbato F, Grumetto L . Monitoring of bisphenol A and bisphenol S in thermal paper receipts from the Italian market and estimated transdermal human intake: A pilot study. Sci Total Environ. 2017; 599-600:68-75. DOI: 10.1016/j.scitotenv.2017.04.192. View

3.
Lin L, Uzunoglu A, Stanciu L . Aminolated and Thiolated PEG-Covered Gold Nanoparticles with High Stability and Antiaggregation for Lateral Flow Detection of Bisphenol A. Small. 2017; 14(10). DOI: 10.1002/smll.201702828. View

4.
Raysyan A, Moerer R, Coesfeld B, Eremin S, Schneider R . Fluorescence polarization immunoassay for the determination of diclofenac in wastewater. Anal Bioanal Chem. 2020; 413(4):999-1007. PMC: 7813709. DOI: 10.1007/s00216-020-03058-w. View

5.
Ramachandran S, Singhal M, McKenzie K, Osborn J, Arjyal A, Dongol S . A Rapid, Multiplexed, High-Throughput Flow-Through Membrane Immunoassay: A Convenient Alternative to ELISA. Diagnostics (Basel). 2016; 3(2):244-60. PMC: 4665536. DOI: 10.3390/diagnostics3020244. View