Abstract

Background: The measurement of micronutrient status is essential to understand the health of individuals and populations, but there are limited data on the stability of micronutrients in whole blood.

Objectives: The objective was to investigate the effects of delayed processing of whole blood on the stability of 25 micronutrient and selected clinical biomarkers.

Methods: Blood from 16 healthy adults was collected into EDTA, lithium heparin (LH), or serum tubes. Samples were processed within 2 hours of collection ("2-hour processed") or mailed overnight (boxed with frozen cold packs) before processing ("24-hour processed"). Micronutrient and clinical biomarker concentrations were quantified with validated methods. The concentration percentage difference between the 2- and 24-hour processed samples was calculated and was compared against quality specifications determined from intra- and interindividual variations.

Results: All analytes had a sample type where the percentage difference concentration between 2-hour and 24-hour processed samples was ≤4% and was acceptable based on calculated limits, including for biomarkers of vitamin A, vitamin D, thiamin, folate, vitamin B-12, iron (ferritin), and zinc status and for selected clinical markers, C-reactive protein, HDL and total cholesterol, and triglycerides. EDTA plasma vitamin C was lower compared to the 2-hour processed sample (geometric mean, 43%; 95% CI: 36%-49%). Pyridoxal-5-phosphate (vitamin B-6 biomarker) decreased, with differences from the 2-hour processed samples of -8% (95% CI: -13% to -2%) and -14% (95% CI: -18% to -9%) in LH plasma and serum, respectively.

Conclusions: In blood collected from adult participants, delayed processing of chilled whole blood for 24 hours did not materially affect the measured concentrations of the majority of micronutrients and selected clinical biomarkers. This suggests that for these analytes, adherence to a 2-hour processing protocol may be unnecessary. This knowledge is valuable and may help to simplify logistics for sample transport and processing of blood samples for micronutrient status assessment.

Citing Articles

Water-Soluble Vitamins Stability by Robust Liquid Chromatography-Mass Spectrometry.

Luo W, Wang D, Tang Y, Cheng Q, Ma X, Yu S Ann Nutr Metab. 2024; 81(1):32-40.

PMID: 39348803 PMC: 11797916. DOI: 10.1159/000541587.


The Impact of Delayed Processing of Chilled Whole Blood Specimens on the Measurement of Nutritional Biomarkers in the United Kingdom National Diet and Nutrition Survey Rolling Programme.

Jones K, Meadows S, Parkington D, Collins D, Bates B, Koulman A J Nutr. 2024; 154(9):2818-2826.

PMID: 39004224 PMC: 11393162. DOI: 10.1016/j.tjnut.2024.07.008.


The Influence of Preanalytical Biospecimen Handling on the Measurement of B Vitamers, Amino Acids, and Other Metabolites in Blood.

Michels K, Weinstein S, Albert P, Black A, Brotzman M, Diaz-Mayoral N Biopreserv Biobank. 2023; 21(5):467-476.

PMID: 36622937 PMC: 10616936. DOI: 10.1089/bio.2022.0053.

References
1.
Hustad S, Eussen S, Midttun O, Ulvik A, van de Kant P, Morkrid L . Kinetic modeling of storage effects on biomarkers related to B vitamin status and one-carbon metabolism. Clin Chem. 2011; 58(2):402-10. DOI: 10.1373/clinchem.2011.174490. View

2.
Pullar J, Bayer S, Carr A . Appropriate Handling, Processing and Analysis of Blood Samples Is Essential to Avoid Oxidation of Vitamin C to Dehydroascorbic Acid. Antioxidants (Basel). 2018; 7(2). PMC: 5836019. DOI: 10.3390/antiox7020029. View

3.
Cuerq C, Peretti N, Chikh K, Mialon A, Guillaumont M, Drai J . Overview of the in vitro stability of commonly measured vitamins and carotenoids in whole blood. Ann Clin Biochem. 2014; 52(Pt 2):259-69. DOI: 10.1177/0004563214542471. View

4.
Talwar D, Quasim T, McMillan D, Kinsella J, Williamson C, OReilly D . Optimisation and validation of a sensitive high-performance liquid chromatography assay for routine measurement of pyridoxal 5-phosphate in human plasma and red cells using pre-column semicarbazide derivatisation. J Chromatogr B Analyt Technol Biomed Life Sci. 2003; 792(2):333-43. DOI: 10.1016/s1570-0232(03)00320-9. View

5.