Background: Validation of self-reported tools, such as physical activity (PA) questionnaires, is crucial. The aim of this study was to determine test-retest reliability, internal consistency, and the concurrent, construct, and predictive validity of the short semi-quantitative Physical Activity Unit 7 item Screener (PAU-7S), using accelerometry as the reference measurement. The effect of linear calibration on PAU-7S validity was tested.
Methods: A randomized sample of 321 healthy children aged 8-16 years (149 boys, 172 girls) from the nationwide representative PASOS study completed the PAU-7S before and after wearing an accelerometer for at least 7 consecutive days. Weight, height, and waist circumference were measured. Cronbach alpha was calculated for internal consistency. Test-retest reliability was determined by intra-class correlation (ICC). Concurrent validity was assessed by ICC and Spearman correlation coefficient between moderate to vigorous PA (MVPA) derived by the PAU-7S and by accelerometer. Concordance between both methods was analyzed by absolute agreement, weighted kappa, and Bland-Altman statistics. Multiple linear regression models were fitted for construct validity and predictive validity was determined by leave-one-out cross-validation.
Results: The PAU-7S overestimated MVPA by 18%, compared to accelerometers (106.5 ± 77.0 vs 95.2 ± 33.2 min/day, respectively). A Cronbach alpha of 0.76 showed an acceptable internal consistency of the PAU-7S. Test-retest reliability was good (ICC 0.71 p < 0.001). Spearman correlation and ICC coefficients of MVPA derived by the PAU-7S and accelerometers increased from 0.31 to 0.62 and 0.20 to 0.62, respectively, after calibration of the PAU-7S. Between-methods concordance improved from a weighted kappa of 0.24 to 0.50 after calibration. A slight reduction in ICC, from 0.62 to 0.60, yielded good predictive validity. Multiple linear regression models showed an inverse association of MVPA with standardized body mass index (β - 0.162; p < 0.077) and waist to height ratio (β - 0.010; p < 0.014). All validity dimensions were somewhat stronger in boys compared to girls.
Conclusion: The PAU-7S shows a good test-retest reliability and acceptable internal consistency. All dimensions of validity increased from poor/fair to moderate/good after calibration. The PAU-7S is a valid instrument for measuring MVPA in children and adolescents.
Trial Registration: Trial registration number ISRCTN34251612 .
Vasileva F, Font-Llado R, Carreras-Badosa G, Lopez-Ros V, Ferrusola-Pastrana A, Lopez-Bermejo A J Funct Morphol Kinesiol. 2024; 9(3).
PMID: 39311262 PMC: 11417929. DOI: 10.3390/jfmk9030154.
Aznar S, Jimenez-Zazo F, Romero-Blanco C, Gomez S, Homs C, Warnberg J PLoS One. 2024; 19(3):e0296816.
PMID: 38489321 PMC: 10942037. DOI: 10.1371/journal.pone.0296816.
Benavente-Marin J, Baron-Lopez F, Gil Barcenilla B, Longo Abril G, Rumbao Aguirre J, Perez-Farinos N PeerJ. 2024; 12:e16990.
PMID: 38468640 PMC: 10926909. DOI: 10.7717/peerj.16990.
Chacon C, Arteaga I, Martinez-Escude A, Rojano I, Lamonja-Vicente N, Caballeria L PLoS One. 2023; 18(10):e0286586.
PMID: 37831682 PMC: 10575486. DOI: 10.1371/journal.pone.0286586.
Monserrat-Mesquida M, Rodenas-Munar M, Gomez S, Warnberg J, Medrano M, Gonzalez-Gross M Nutrients. 2023; 15(16).
PMID: 37630807 PMC: 10459595. DOI: 10.3390/nu15163617.