» Articles » PMID: 33847797

Highly Cross-linked Polyethylene in Primary Total Knee Arthroplasty is Associated with a Lower Rate of Revision for Aseptic Loosening: a Meta-analysis of 962,467 Cases

Overview
Date 2021 Apr 13
PMID 33847797
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The evolution in total knee arthroplasty (TKA) includes the highly cross-linked polyethylene (HXLPE) which has been reported as an effective manner to reduce the wear of the polyethylene and the osteolysis. The purpose of the present study is to synthesize the results of comparative studies between HXLPE and conventional polyethylenes and determine their effect in primary TKA.

Methods: The US National Library of Medicine (PubMed/MEDLINE) and the Cochrane Database of Systematic Reviews were queried for publications utilizing the following keywords: "cross-linked", "polyethylene", "HXLPE", "conventional", "total knee arthroplasty", "TKA", "total knee replacement" and "TKR" combined with Boolean operators AND and OR.

Results: Ten studies met the inclusion criteria and were included in the present meta-analysis with 962,467 patients. No significant difference was found regarding the revision rate for any reason between the patients who received HXLPE and those with conventional liner (OR 0.67; 95% CI 0.39-1.18; I: 97.7%). In addition, there was no difference regarding the radiolucent lines between the two types of liners (OR 0.54; 95% CI 0.20-1.49; I: 69.4%). However, with data coming from seven studies enrolling a total of 411,543 patients, it was demonstrated that patients who received HXLPE were less likely to be revised due to aseptic loosening compared to the patients with conventional liners (OR 0.35; 95% CI 0.31-0.39; I: 0.0%).

Conclusion: The present meta-analysis showed that regarding the overall revision rate and radiographic outcomes there was no significant difference between the two types of liners. On the other hand, the significantly less revision rate due to loosening supports the routine continued use of HXLPE in primary TKA.

Citing Articles

The influence of implant factors on patient outcomes in primary total knee arthroplasty.

Van Meirhaeghe J, Harris I, Cuthbert A, Lorimer M, McAuliffe M, Adie S J Orthop. 2024; 58:154-160.

PMID: 39157416 PMC: 11326491. DOI: 10.1016/j.jor.2024.07.011.


Comprehensive evaluation of risk factors for aseptic loosening in cemented total knee arthroplasty: A systematic review and meta-analysis.

Yao K, Chen Y J Exp Orthop. 2024; 11(3):e12095.

PMID: 39035847 PMC: 11260281. DOI: 10.1002/jeo2.12095.


Stable polyethylene inlay fixation and low polyethylene wear rate in fixed-bearing total knee arthroplasty at five to six years' follow-up.

Jurgens-Lahnstein J, Petersen E, Rytter S, Madsen F, Soballe K, Stilling M Bone Joint Res. 2024; 13(5):226-236.

PMID: 38719208 PMC: 11090217. DOI: 10.1302/2046-3758.135.BJR-2023-0126.R1.


[Finite element analysis of artificial ankle elastic improved inserts].

Xu Z, Li Y, Zou G, Jin Y, Rao J, Tian S Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2023; 37(11):1361-1369.

PMID: 37987045 PMC: 10662418. DOI: 10.7507/1002-1892.202307042.


Long leg radiographs underestimate the degree of constitutional varus limb alignment and joint line obliquity in comparison with computed tomography: a radiographic study.

Tarassoli P, Corban L, Wood J, Sergis A, Chen D, MacDessi S Knee Surg Sports Traumatol Arthrosc. 2023; 31(11):4755-4765.

PMID: 37490128 DOI: 10.1007/s00167-023-07505-w.


References
1.
Sneag D, Bogner E, Potter H . Magnetic resonance imaging evaluation of the painful total knee arthroplasty. Semin Musculoskelet Radiol. 2015; 19(1):40-8. DOI: 10.1055/s-0034-1396766. View

2.
Sharkey P, Lichstein P, Shen C, Tokarski A, Parvizi J . Why are total knee arthroplasties failing today--has anything changed after 10 years?. J Arthroplasty. 2014; 29(9):1774-8. DOI: 10.1016/j.arth.2013.07.024. View

3.
Ries M, Pruitt L . Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene. Clin Orthop Relat Res. 2005; 440:149-56. DOI: 10.1097/01.blo.0000185310.59202.e5. View

4.
Lachiewicz P, Geyer M . The use of highly cross-linked polyethylene in total knee arthroplasty. J Am Acad Orthop Surg. 2011; 19(3):143-51. DOI: 10.5435/00124635-201103000-00003. View

5.
Bragdon C, Doerner M, Martell J, Jarrett B, Palm H, Malchau H . The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA. Clin Orthop Relat Res. 2012; 471(2):393-402. PMC: 3549171. DOI: 10.1007/s11999-012-2604-0. View