The Use of Highly Cross-linked Polyethylene in Total Knee Arthroplasty

Overview
Publisher Wolters Kluwer
Date 2011 Mar 4
PMID 21368095
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Polyethylene wear, with resultant particle-induced osteolysis, is a cause of late failure of total knee arthroplasty. The causes of both wear and osteolysis are multifactorial; still, improvements in the polyethylene liner have been investigated. Available highly cross-linked polyethylene tibial liners and patellar prostheses differ greatly in the amount and method of irradiation, thermal treatments, and sterilization techniques they undergo. Several varieties of highly cross-linked polyethylene reduce the gravimetric and volumetric wear of tibial liners in knee simulator studies. However, reduced fracture toughness and the generation of smaller and possibly more reactive particles also have been reported with some varieties of polyethylene. Clinical studies of the use of highly cross-linked polyethylene in total knee arthroplasty are limited. Two nonrandomized trials of highly cross-linked polyethylene in total knee arthroplasty have reported a nonsignificant decrease in radiolucent lines at 2 and 5 years, respectively. The risks of using highly cross-linked polyethylene include fracture of the liner or of a posterior-stabilized tibial post, liner dislodgement or locking mechanism disruption, and possibly more osteolysis. Highly cross-linked polyethylene tibial liners may be considered for younger, more active patients. However, until additional clinical results are available, a cautious approach is warranted to the widespread use of highly cross-linked polyethylene in total knee arthroplasty.

Citing Articles

Vitamin E-stabilized polyethylene shows similar survival rates at minimum 7-year follow-up compared to conventional polyethylene in primary total knee arthroplasty.

Bistolfi A, Spezia M, Cipolla A, Bonera M, Mellano D, Banci L J Exp Orthop. 2024; 11(3):e12106.

PMID: 39239569 PMC: 11375329. DOI: 10.1002/jeo2.12106.


Patellar management during total knee arthroplasty: a review.

McConaghy K, Derr T, Molloy R, Klika A, Kurtz S, Piuzzi N EFORT Open Rev. 2021; 6(10):861-871.

PMID: 34760286 PMC: 8559560. DOI: 10.1302/2058-5241.6.200156.


Highly cross-linked polyethylene in primary total knee arthroplasty is associated with a lower rate of revision for aseptic loosening: a meta-analysis of 962,467 cases.

Gkiatas I, Karasavvidis T, Sharma A, Xiang W, Malahias M, Chalmers B Arch Orthop Trauma Surg. 2021; 142(6):1177-1184.

PMID: 33847797 DOI: 10.1007/s00402-021-03887-z.


Literature review of the causes of pain following total knee replacement surgery: prosthesis, inflammation and arthrofibrosis.

Yin Li C, Chung K, Ali O, Chung N, Li C EFORT Open Rev. 2020; 5(9):534-543.

PMID: 33072405 PMC: 7528670. DOI: 10.1302/2058-5241.5.200031.


Nontraumatic fracture of the polyethylene tibial post in a bi-cruciate stabilized total knee prosthesis.

Renson D, Lenaerts W, Feyen J Arthroplast Today. 2019; 5(3):284-287.

PMID: 31516966 PMC: 6728542. DOI: 10.1016/j.artd.2019.06.001.