» Articles » PMID: 33747666

An Accurate QRS Complex and P Wave Detection in ECG Signals Using Complete Ensemble Empirical Mode Decomposition Approach

Overview
Journal IEEE Access
Date 2021 Mar 22
PMID 33747666
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

We developed a novel method for QRS complex and P wave detection in the electrocardiogram (ECG) signal. The approach reconstructs two different signals for the purpose of QRS and P wave detection from the modes obtained by the complete ensemble empirical mode decomposition with adaptive noise, taking only those modes that best represent the signal dynamics. This approach eliminates the need for conventional filtering. We first detect QRS complex locations, followed by removal of QRS complexes from the reconstructed signal to enable P wave detection. We introduce a novel method of P wave detection from both the positive and negative amplitudes of the ECG signal and an adaptive P wave search approach to find the true P wave. Our detection method automatically identifies P waves without prior information. The proposed method was validated on two well-known annotated databases-the MIT BIH Arrythmia database (MITDB) and The QT database (QTDB). The QRS detection algorithm resulted in 99.96% sensitivity, 99.9% positive predictive value, and an error of 0.13% on all validation databases. The P wave detection method had better performance when compared to other well-known methods. The performance of our P wave detection on the QTDB showed a sensitivity of 99.96%, a positive predictive value of 99.47%, and the mean error in P peak detection was less than or equal to one sample (4 ms) on average.

Citing Articles

Detection of Cognitive Performance Deterioration Due to Cold-Air Exposure in Females Using Wearable Electrodermal Activity and Electrocardiogram.

Kong Y, McNaboe R, Hossain M, Posada-Quintero H, Diaz K, Chon K Biosensors (Basel). 2025; 15(2).

PMID: 39996980 PMC: 11852572. DOI: 10.3390/bios15020078.


Does Heart Rate Variability Predict Impairment of Operational Performance in Divers?.

Freiberger J, Derrick B, Chon K, Hossain M, Posada-Quintero H, Cooter M Sensors (Basel). 2024; 24(23).

PMID: 39686263 PMC: 11644904. DOI: 10.3390/s24237726.


Sex differences in autonomic functions and cognitive performance during cold-air exposure and cold-water partial immersion.

Kong Y, Hossain M, McNaboe R, Posada-Quintero H, Daley M, Diaz K Front Physiol. 2024; 15:1463784.

PMID: 39479308 PMC: 11521960. DOI: 10.3389/fphys.2024.1463784.


Peak detection in intracranial pressure signal waveforms: a comparative study.

Wei M, Krakauskaite S, Subramanian S, Scalzo F Biomed Eng Online. 2024; 23(1):61.

PMID: 38915091 PMC: 11194974. DOI: 10.1186/s12938-024-01245-9.


Multisensor Integrated Platform Based on MEMS Charge Variation Sensing Technology for Biopotential Acquisition.

Irrera F, Gumiero A, Zampogna A, Boscari F, Avogaro A, Gazzanti Pugliese di Cotrone M Sensors (Basel). 2024; 24(5).

PMID: 38475089 PMC: 10934124. DOI: 10.3390/s24051554.


References
1.
Bashar S, Walkey A, McManus D, Chon K . VERB: VFCDM-Based Electrocardiogram Reconstruction and Beat Detection Algorithm. IEEE Access. 2019; 7:13856-13866. PMC: 6860377. DOI: 10.1109/ACCESS.2019.2894092. View

2.
Martinez J, Almeida R, Olmos S, Rocha A, Laguna P . A wavelet-based ECG delineator: evaluation on standard databases. IEEE Trans Biomed Eng. 2004; 51(4):570-81. DOI: 10.1109/TBME.2003.821031. View

3.
Chong J, Esa N, McManus D, Chon K . Arrhythmia discrimination using a smart phone. IEEE J Biomed Health Inform. 2015; 19(3):815-24. PMC: 6599713. DOI: 10.1109/JBHI.2015.2418195. View

4.
Mozaffarian D, Benjamin E, Go A, Arnett D, Blaha M, Cushman M . Heart disease and stroke statistics--2015 update: a report from the American Heart Association. Circulation. 2014; 131(4):e29-322. DOI: 10.1161/CIR.0000000000000152. View

5.
Lenis G, Pilia N, Oesterlein T, Luik A, Schmitt C, Dossel O . P wave detection and delineation in the ECG based on the phase free stationary wavelet transform and using intracardiac atrial electrograms as reference. Biomed Tech (Berl). 2015; 61(1):37-56. DOI: 10.1515/bmt-2014-0161. View