» Articles » PMID: 33137901

An Adaptive Median Filter Based on Sampling Rate for R-Peak Detection and Major-Arrhythmia Analysis

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 Nov 3
PMID 33137901
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

With the advancement of the Internet of Medical Things technology, many vital sign-sensing devices are being developed. Among the diverse healthcare devices, portable electrocardiogram (ECG) measuring devices are being developed most actively with the recent development of sensor technology. These ECG measuring devices use different sampling rates according to the hardware conditions, which is the first variable to consider in the development of ECG analysis technology. Herein, we propose an R-point detection method using an adaptive median filter based on the sampling rate and analyze major arrhythmias using the signal characteristics. First, the sliding window and median filter size are determined according to the set sampling rate, and a wider median filter is applied to the QRS section with high variance within the sliding window. Then, the R point is detected by subtracting the filtered signal from the original signal. Methods for detecting major arrhythmias using the detected R point are proposed. Different types of ECG signals were used for a simulation, including ECG signals from the MIT-BIH arrhythmia database and MIT-BIH atrial fibrillation database, signals generated by a simulator, and actual measured signals with different sampling rates. The experimental results indicated the effectiveness of the proposed R-point detection method and arrhythmia analysis technique.

Citing Articles

Certain investigation on hybrid neural network method for classification of ECG signal with the suitable a FIR filter.

Jayaraman Rajendiran D, Ganesh Babu C, Priyadharsini K, Karthi S Sci Rep. 2024; 14(1):15087.

PMID: 38956261 PMC: 11219891. DOI: 10.1038/s41598-024-65849-w.


Robust human locomotion and localization activity recognition over multisensory.

Khan D, Alonazi M, Abdelhaq M, Al Mudawi N, Algarni A, Jalal A Front Physiol. 2024; 15:1344887.

PMID: 38449788 PMC: 10915014. DOI: 10.3389/fphys.2024.1344887.


Multilayer Perceptron-Based Real-Time Intradialytic Hypotension Prediction Using Patient Baseline Information and Heart-Rate Variation.

Bae T, Kim M, Park J, Kwon K, Kim K Int J Environ Res Public Health. 2022; 19(16).

PMID: 36012006 PMC: 9408052. DOI: 10.3390/ijerph191610373.


Lessons from a multicenter clinical trial with an approved wearable electrocardiogram: issues and practical considerations.

Huh K, Jeong S, Yoo H, Piao M, Ryu H, Kim H Transl Clin Pharmacol. 2022; 30(2):87-98.

PMID: 35800668 PMC: 9253449. DOI: 10.12793/tcp.2022.30.e7.


[Heartbeat-aware convolutional neural network for R-peak detection of wearable device ECG data].

Tan H, Lai J, Wang Z, Ji L, Zhang Y, Wang J Nan Fang Yi Ke Da Xue Xue Bao. 2022; 42(3):375-383.

PMID: 35426801 PMC: 9010988. DOI: 10.12122/j.issn.1673-4254.2022.03.09.


References
1.
Elgendi M, Mohamed A, Ward R . Efficient ECG Compression and QRS Detection for E-Health Applications. Sci Rep. 2017; 7(1):459. PMC: 5428727. DOI: 10.1038/s41598-017-00540-x. View

2.
Poli R, Cagnoni S, Valli G . Genetic design of optimum linear and nonlinear QRS detectors. IEEE Trans Biomed Eng. 1995; 42(11):1137-41. DOI: 10.1109/10.469381. View

3.
Hamilton P, Tompkins W . Quantitative investigation of QRS detection rules using the MIT/BIH arrhythmia database. IEEE Trans Biomed Eng. 1986; 33(12):1157-65. DOI: 10.1109/tbme.1986.325695. View

4.
Fantoni C, Raffa S, Regoli F, Giraldi F, La Rovere M, Prentice J . Cardiac resynchronization therapy improves heart rate profile and heart rate variability of patients with moderate to severe heart failure. J Am Coll Cardiol. 2005; 46(10):1875-82. DOI: 10.1016/j.jacc.2005.06.081. View

5.
Hossain B, Bashar S, Walkey A, McManus D, Chon K . An Accurate QRS complex and P wave Detection in ECG Signals using Complete Ensemble Empirical Mode Decomposition Approach. IEEE Access. 2021; 7:128869-128880. PMC: 7970665. DOI: 10.1109/access.2019.2939943. View