» Articles » PMID: 33343033

A Multi-Mode System for Myocardial Functional and Physiological Assessment During Ex Situ Heart Perfusion

Abstract

Ex situ heart perfusion (ESHP) has proven to be an important and valuable step toward better preservation of donor hearts for heart transplantation. Currently, few ESHP systems allow for a convenient functional and physiological evaluation of the heart. We sought to establish a simple system that provides functional and physiological assessment of the heart during ESHP. The ESHP circuit consists of an oxygenator, a heart-lung machine, a heater-cooler unit, an anesthesia gas blender, and a collection funnel. Female Yorkshire pig hearts (n = 10) had del Nido cardioplegia (4°C) administered, excised, and attached to the perfusion system. Hearts were perfused retrogradely into the aortic root for 2 hours before converting the system to an isovolumic mode or a working mode for further 2 hours. Blood samples were analyzed to measure metabolic parameters. During the isovolumic mode (n = 5), a balloon inserted in the left ventricular (LV) cavity was inflated so that an end-diastolic pressure of 6-8 mmHg was reached. During the working mode (n = 5), perfusion in the aortic root was redirected into left atrium (LA) using a compliance chamber which maintained an LA pressure of 6-8 mmHg. Another compliance chamber was used to provide an afterload of 40-50 mmHg. Hemodynamic and metabolic conditions remained stable and consistent for a period of 4 hours of ESHP in both isovolumic mode (LV developed pressure: 101.0 ± 3.5 vs. 99.7 ± 6.8 mmHg, = .979, at 2 and 4 hours, respectively) and working mode (LV developed pressure: 91.0 ± 2.6 vs. 90.7 ± 2.5 mmHg, = .942, at 2 and 4 hours, respectively). The present study proposed a novel ESHP system that enables comprehensive functional and metabolic assessment of large mammalian hearts. This system allowed for stable myocardial function for up to 4 hours of perfusion, which would offer great potential for the development of translational therapeutic protocols to improve dysfunctional donated hearts.

Citing Articles

Mitochondrial transplantation normalizes transcriptomic and proteomic shift associated with ischemia reperfusion injury in neonatal hearts donated after circulatory death.

Doulamis I, Tzani A, Alemany V, Nomoto R, Celik A, Recco D Sci Rep. 2024; 14(1):31236.

PMID: 39732955 PMC: 11682362. DOI: 10.1038/s41598-024-82578-2.


A modified intraventricular balloon method for functional assessment of hearts from donation after circulatory death.

Kadowaki S, Parker M, Wang J, Mueller B, Steve Fan C, Li J JTCVS Open. 2024; 18:104-117.

PMID: 38690439 PMC: 11056455. DOI: 10.1016/j.xjon.2024.01.009.


Academic Perfusion at Its Best and a New Tradition.

Wong R J Extra Corpor Technol. 2020; 52(4):259-260.

PMID: 33343026 PMC: 7728495. DOI: 10.1182/ject-524fte.

References
1.
White C, Hasanally D, Mundt P, Li Y, Xiang B, Klein J . A whole blood-based perfusate provides superior preservation of myocardial function during ex vivo heart perfusion. J Heart Lung Transplant. 2014; 34(1):113-121. DOI: 10.1016/j.healun.2014.09.021. View

2.
Trahanas J, Witer L, Alghanem F, Bryner B, Iyengar A, Hirschl J . Achieving 12 Hour Normothermic Ex Situ Heart Perfusion: An Experience of 40 Porcine Hearts. ASAIO J. 2016; 62(4):470-6. PMC: 4925299. DOI: 10.1097/MAT.0000000000000382. View

3.
White C, Avery E, Muller A, Hatami S, Li Y, Le H . Impact of Reperfusion Calcium and pH on the Resuscitation of Hearts Donated After Circulatory Death. Ann Thorac Surg. 2016; 103(1):122-130. DOI: 10.1016/j.athoracsur.2016.05.084. View

4.
Suehiro K, Mohri M, Yamaguchi H, Takagaki M, Hisamochi K, Morimoto T . Posttransplant function of a nonbeating heart is predictable by an ex vivo perfusion method. Ann Thorac Surg. 2001; 71(1):278-83. DOI: 10.1016/s0003-4975(00)01939-1. View

5.
Kaliyev R, Bekbossynov S, Nurmykhametova Z . Sixteen-Hour Ex Vivo Donor Heart Perfusion During Long-Distance Transportation for Heart Transplantation. Artif Organs. 2018; 43(3):319-320. PMC: 6590649. DOI: 10.1111/aor.13359. View