» Articles » PMID: 33252719

Automated Measurement of Hip-knee-ankle Angle on the Unilateral Lower Limb X-rays Using Deep Learning

Overview
Publisher Springer
Date 2020 Nov 30
PMID 33252719
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Significant inherent extra-articular varus angulation is associated with abnormal postoperative hip-knee-ankle (HKA) angle. At present, HKA is manually measured by orthopedic surgeons and it increases the doctors' workload. To automatically determine HKA, a deep learning-based automated method for measuring HKA on the unilateral lower limb X-rays was developed and validated. This study retrospectively selected 398 double lower limbs X-rays during 2018 and 2020 from Jilin University Second Hospital. The images (n = 398) were cropped into unilateral lower limb images (n = 796). The deep neural network was used to segment the head of hip, the knee, and the ankle in the same image, respectively. Then, the mean square error of distance between each internal point of each organ and the organ's boundary was calculated. The point with the minimum mean square error was set as the central point of the organ. HKA was determined using the coordinates of three organs' central points according to the law of cosines. In a quantitative analysis, HKA was measured manually by three orthopedic surgeons with a high consistency (176.90 °  ± 12.18°, 176.95 °  ± 12.23°, 176.87 °  ± 12.25°) as evidenced by the Kandall's W of 0.999 (p < 0.001). Of note, the average measured HKA by them (176.90 °  ± 12.22°) served as the ground truth. The automatically measured HKA by the proposed method (176.41 °  ± 12.08°) was close to the ground truth, showing no significant difference. In addition, intraclass correlation coefficient (ICC) between them is 0.999 (p < 0.001). The average of difference between prediction and ground truth is 0.49°. The proposed method indicates a high feasibility and reliability in clinical practice.

Citing Articles

HKA-Net: clinically-adapted deep learning for automated measurement of hip-knee-ankle angle on lower limb radiography for knee osteoarthritis assessment.

Kim Y, Han B, Kim J, Sa J, Hong J, Son Y J Orthop Surg Res. 2024; 19(1):777.

PMID: 39568048 PMC: 11580353. DOI: 10.1186/s13018-024-05265-y.


Artificial intelligence-based assessment of leg axis parameters shows excellent agreement with human raters: A systematic review and meta-analysis.

Salzmann M, Hassan Tarek H, Prill R, Becker R, Schreyer A, Hable R Knee Surg Sports Traumatol Arthrosc. 2024; 33(1):177-190.

PMID: 39033340 PMC: 11716349. DOI: 10.1002/ksa.12362.


Automated weight-bearing foot measurements using an artificial intelligence-based software.

Lassalle L, Regnard N, Ventre J, Marty V, Clovis L, Zhang Z Skeletal Radiol. 2024; 54(2):229-241.

PMID: 38880791 DOI: 10.1007/s00256-024-04726-z.


Automatic measurement of lower limb alignment in portable devices based on deep learning for knee osteoarthritis.

Yang J, Ren P, Xin P, Wang Y, Ma Y, Liu W J Orthop Surg Res. 2024; 19(1):232.

PMID: 38594698 PMC: 11005281. DOI: 10.1186/s13018-024-04658-3.


Automatic Segmentation and Radiologic Measurement of Distal Radius Fractures Using Deep Learning.

Lee S, Kim K, Kim Y, Jeon J, Lee G, Kim K Clin Orthop Surg. 2024; 16(1):113-124.

PMID: 38304219 PMC: 10825247. DOI: 10.4055/cios23130.


References
1.
Greene W . Genu varum and genu valgum in children: differential diagnosis and guidelines for evaluation. Compr Ther. 1996; 22(1):22-9. View

2.
McKinney S, Sieniek M, Godbole V, Godwin J, Antropova N, Ashrafian H . International evaluation of an AI system for breast cancer screening. Nature. 2020; 577(7788):89-94. DOI: 10.1038/s41586-019-1799-6. View

3.
Radtke K, Becher C, Noll Y, Ostermeier S . Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg. 2009; 130(4):451-7. DOI: 10.1007/s00402-009-0999-1. View

4.
Lazennec J, Chometon Q, Folinais D, Robbins C, Eslam Pour A . Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?. Int Orthop. 2016; 41(5):917-924. DOI: 10.1007/s00264-016-3340-y. View

5.
Chaibi Y, Cresson T, Aubert B, Hausselle J, Neyret P, Hauger O . Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Engin. 2011; 15(5):457-66. DOI: 10.1080/10255842.2010.540758. View