» Articles » PMID: 32996669

Retrospective Analysis of the Impact of Respiratory Motion in Treatment Margins for Frameless Lung SBRT Based on Respiratory-correlated CBCT Data-sets

Overview
Date 2020 Sep 30
PMID 32996669
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate the impact of respiratory motion in the treatment margins for lung SBRT frameless treatments and to validate our treatment margins using 4D CBCT data analysis.

Methods: Two hundred and twenty nine fractions with early stage NSCLC were retrospectively analyzed. All patients were treated in frameless and free breathing conditions. The treatment margins were calculated according to van Herk equation in Mid-Ventilation. For each fraction, three 4D CBCT scans, pre- and postcorrection, and posttreatment, were acquired to assess target baseline shift, target localization accuracy and intra-fraction motion errors. A bootstrap analysis was performed to assess the minimum number of patients required to define treatment margins.

Results: The retrospectively calculated target-baseline shift, target localization accuracy and intra-fraction motion errors agreed with the literature. The best tailored margins to our cohort of patients were retrospectively computed and resulted in agreement with already published data. The bootstrap analysis showed that fifteen patients were enough to assess treatment margins.

Conclusions: The treatment margins applied to our patient's cohort resulted in good agreement with the retrospectively calculated margins based on 4D CBCT data. Moreover, the bootstrap analysis revealed to be a promising method to verify the reliability of the applied treatment margins for safe lung SBRT delivery.

Citing Articles

A review on 4D cone-beam CT (4D-CBCT) in radiation therapy: Technical advances and clinical applications.

Zhang Y, Jiang Z, Zhang Y, Ren L Med Phys. 2024; 51(8):5164-5180.

PMID: 38922912 PMC: 11321939. DOI: 10.1002/mp.17269.


A review of surface guidance in extracranial stereotactic body radiotherapy (SBRT/SABR) for set-up and intra-fraction motion management.

Lawler G Tech Innov Patient Support Radiat Oncol. 2022; 21:23-26.

PMID: 35079644 PMC: 8777133. DOI: 10.1016/j.tipsro.2022.01.001.


On the evaluation of mobile target trajectory between four-dimensional computer tomography and four-dimensional cone-beam computer tomography.

Baley C, Kirby N, Wagner T, Papanikolaou N, Myers P, Rasmussen K J Appl Clin Med Phys. 2021; 22(7):198-207.

PMID: 34085384 PMC: 8292704. DOI: 10.1002/acm2.13310.

References
1.
Lin C, Xu S, Yao W, Wu Y, Fang J, Wu V . Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients. J Med Radiat Sci. 2016; 64(2):106-113. PMC: 5454330. DOI: 10.1002/jmrs.189. View

2.
Seppenwoolde Y, Shirato H, Kitamura K, Shimizu S, Van Herk M, Lebesque J . Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys. 2002; 53(4):822-34. DOI: 10.1016/s0360-3016(02)02803-1. View

3.
Senthi S, Haasbeek C, Slotman B, Senan S . Outcomes of stereotactic ablative radiotherapy for central lung tumours: a systematic review. Radiother Oncol. 2013; 106(3):276-82. DOI: 10.1016/j.radonc.2013.01.004. View

4.
Liang Z, Yang J, Liu H, Yin Z, Zhang S, Peng H . Real-time tumor motion monitoring and PTV margin determination in lung SBRT treatment. Acta Oncol. 2019; 58(12):1786-1789. DOI: 10.1080/0284186X.2019.1648862. View

5.
Keall P, Mageras G, Balter J, Emery R, Forster K, Jiang S . The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys. 2006; 33(10):3874-900. DOI: 10.1118/1.2349696. View