Mid-ventilation CT Scan Construction from Four-dimensional Respiration-correlated CT Scans for Radiotherapy Planning of Lung Cancer Patients

Overview
Specialties Oncology
Radiology
Date 2006 Jul 26
PMID 16863933
Citations 63
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Four-dimensional (4D) respiration-correlated imaging techniques can be used to obtain (respiration) artifact-free computed tomography (CT) images of the thorax. Current radiotherapy planning systems, however, do not accommodate 4D-CT data. The purpose of this study was to develop a simple, new concept to incorporate patient-specific motion information, using 4D-CT scans, in the radiotherapy planning process of lung cancer patients to enable smaller error margins.

Methods And Materials: A single CT scan was selected from the 4D-CT data set. This scan represented the tumor in its time-averaged position over the respiratory cycle (the mid-ventilation CT scan). To select the appropriate CT scan, two methods were used. First, the three-dimensional tumor motion was analyzed semiautomatically to calculate the mean tumor position and the corresponding respiration phase. An alternative automated method was developed to select the correct CT scan using the diaphragm motion.

Results: Owing to hysteresis, mid-ventilation selection using the three-dimensional tumor motion had a tumor position accuracy (with respect to the mean tumor position) better than 1.1 +/- 1.1 mm for all three directions (inhalation and exhalation). The accuracy in the diaphragm motion method was better than 1.1 +/- 1.1 mm. Conventional free-breathing CT scanning had an accuracy better than 0 +/- 3.9 mm. The mid-ventilation concept can result in an average irradiated volume reduction of 20% for tumors with a diameter of 40 mm.

Conclusion: Tumor motion and the diaphragm motion method can be used to select the (artifact-free) mid-ventilation CT scan, enabling a significant reduction of the irradiated volume.

Citing Articles

Improving motion management in radiation therapy: findings from a workshop and survey in Australia and New Zealand.

Claridge Mackonis E, Stensmyr R, Poldy R, White P, Moutrie Z, Gorjiara T Phys Eng Sci Med. 2024; 47(3):813-820.

PMID: 38805104 PMC: 11408578. DOI: 10.1007/s13246-024-01405-0.


Individualized breathing trace quality assurance for lung radiotherapy patients undergoing 4DCT simulation.

Rijken J, Hu Y, Hiscoke K J Appl Clin Med Phys. 2023; 24(6):e13929.

PMID: 36807511 PMC: 10243311. DOI: 10.1002/acm2.13929.


Accuracy and consistency of intensity-based deformable image registration in 4DCT for tumor motion estimation in liver radiotherapy planning.

Tascon-Vidarte J, Stick L, Josipovic M, Risum S, Jomier J, Erleben K PLoS One. 2022; 17(7):e0271064.

PMID: 35802593 PMC: 9269460. DOI: 10.1371/journal.pone.0271064.


Management of Motion and Anatomical Variations in Charged Particle Therapy: Past, Present, and Into the Future.

Pakela J, Knopf A, Dong L, Rucinski A, Zou W Front Oncol. 2022; 12:806153.

PMID: 35356213 PMC: 8959592. DOI: 10.3389/fonc.2022.806153.


Four-Dimensional Computed Tomography-Based Correlation of Respiratory Motion of Lung Tumors With Implanted Fiducials and an External Surrogate.

Willmann J, Sidiqi B, Wang C, Czmielewski C, Li H, Dick-Godfrey R Adv Radiat Oncol. 2022; 7(3):100885.

PMID: 35198837 PMC: 8792087. DOI: 10.1016/j.adro.2021.100885.