A Novel Simple Approach for Incorporation of Respiratory Motion in Stereotactic Treatments of Lung Tumors

Overview
Journal Radiother Oncol
Specialties Oncology
Radiology
Date 2010 Nov 5
PMID 21047693
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: An internal target volume (ITV) is often used for incorporating tumor motion into radiotherapy planning but it overestimates the margins necessary for breathing motion. We describe a pragmatic approach using maximum- and minimum-intensity projections (MIP and Min-IP) only, for reducing ITVs in stereotactic radiotherapy by using dosimetric margins that compensate for motion-induced dose blurring.

Patients And Method: We studied tumor motion characteristics from 26 repeat 4DCT scans derived from 10 patients. These were used to calculate the shift in cranio-caudal direction of the 80% isodose due to dose blurring of the time-averaged dose distribution caused by respiratory motion. The dosimetric margins necessary to compensate for dose blurring were calculated relative to the ITV, which can be determined efficiently using the MIP. Peak-to-peak motion amplitude was determined using the MIP and Min-IP. A programmable respiratory motion phantom was used to investigate imaging artifacts in determining the ITV for realistic motion patterns. Dose profiles were both calculated and measured in lung- and water-equivalent tissue.

Results: Using margins for the 80% dose level permitted the use of smaller target volumes relative to the use of ITV-based volumes, with (i) greater reductions seen at the end-inspiration edge than at expiration side due to asymmetric breathing motion patterns and (ii) a linear relationship seen with breathing amplitude. The average reduction of the ITV at a 95% confidence level is given by 0.2×A(pp)-1.3 mm at expiration side, where A(pp) is the peak-to-peak breathing amplitude, and 0.3×A(pp)-2.2 mm at inspiration side. Dosimetric margins did not differ significantly between water-equivalent and lung tissue for 80% isodose.

Conclusion: A simple margin recipe for breathing motion linear with breathing amplitude can be used to calculate the ITV reductions achievable for stereotactic radiotherapy of lung tumors.

Citing Articles

Retrospective analysis of the impact of respiratory motion in treatment margins for frameless lung SBRT based on respiratory-correlated CBCT data-sets.

Thengumpallil S, Racine D, Germond J, Peguret N, Bourhis J, Bochud F J Appl Clin Med Phys. 2020; 21(10):170-178.

PMID: 32996669 PMC: 7592980. DOI: 10.1002/acm2.13034.


Four-dimensional measurement of the displacement of metal clips or postoperative surgical staples during 320-multislice computed tomography scanning of gastric cancer.

Yamashita H, Okuma K, Takahashi W, Sakumi A, Haga A, Ino K Radiat Oncol. 2012; 7:137.

PMID: 22883343 PMC: 3488031. DOI: 10.1186/1748-717X-7-137.


A 4D IMRT planning method using deformable image registration to improve normal tissue sparing with contemporary delivery techniques.

Li X, Wang X, Li Y, Zhang X Radiat Oncol. 2011; 6:83.

PMID: 21771333 PMC: 3162508. DOI: 10.1186/1748-717X-6-83.