» Articles » PMID: 32887390

Customized 3D-Printed Titanium Mesh Developed to Regenerate a Complex Bone Defect in the Aesthetic Zone: A Case Report Approached with a Fully Digital Workflow

Overview
Publisher MDPI
Date 2020 Sep 5
PMID 32887390
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Alveolar-ridge augmentation, anterior aesthetics, and digital technologies are probably the most popular topics in the dental-implant field. The aim of this report is to present a clinical case of severe atrophy of the anterior maxilla in a younger female patient, treated with a titanium membrane customized with computer-aided design/computer-aided manufacturing (CAD/CAM), simultaneous guided implant placement, and a fully digital workflow. A young female patient with a history of maxillary trauma was treated and followed-up for 1 year after implant placement. A narrow implant was inserted in a prosthetically driven position with the aid of computer-guided surgery. In the same surgical section, a customized implantable titanium mesh was applied. The scaffold was designed according to the contralateral maxillary outline in order to recreate a favorable maxillary bone volume. Finally, highly aesthetic, CAD/CAM, metal-free restorations were delivered using novel digital technologies.

Citing Articles

The Early Exposure Rate and Vertical Bone Gain of Titanium Mesh for Maxillary Bone Regeneration: A Systematic Review and Meta-Analysis.

Lorusso F, Gehrke S, Alla I, Tari S, Scarano A Dent J (Basel). 2025; 13(2).

PMID: 39996926 PMC: 11854525. DOI: 10.3390/dj13020052.


A comparative quantitative assessment of 3D-printed PEKK and PEEK thin meshes in customized alveolar bone augmentation.

Zhu X, Chen C, Hua Y, Xu X, Song P, Wang R BMC Oral Health. 2024; 24(1):1304.

PMID: 39468497 PMC: 11520829. DOI: 10.1186/s12903-024-04994-0.


Customized 3D-Printed Mesh, Membrane, Bone Substitute, and Dental Implant Applied to Guided Bone Regeneration in Oral Implantology: A Narrative Review.

Di Spirito F, Giordano F, Di Palo M, Ferraro C, Cecere L, Frucci E Dent J (Basel). 2024; 12(10).

PMID: 39452431 PMC: 11506345. DOI: 10.3390/dj12100303.


Clinical Study of 14 Cases of Bone Augmentation with Selective Laser Melting Titanium Mesh Plates.

Takahashi A, Inoue K, Imagawa-Fujimura N, Matsumoto K, Yamada K, Sawai Y Materials (Basel). 2023; 16(21).

PMID: 37959439 PMC: 10648651. DOI: 10.3390/ma16216842.


Minimally Invasive Treatment of Lateral Incisors with Guided One-Piece or Two-Piece Titanium-Made Narrow Diameter Implants: A Retrospective Comparative Study with Up to Two Years Follow-Up.

Zadrozny L, Gorski B, Baldoni E, Lumbau A, Meloni S, Pisano M J Clin Med. 2023; 12(11).

PMID: 37297907 PMC: 10253420. DOI: 10.3390/jcm12113711.


References
1.
Tallarico M, Martinolli M, Kim Y, Cocchi F, Meloni S, Alushi A . Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial. Dent J (Basel). 2019; 7(2). PMC: 6631019. DOI: 10.3390/dj7020041. View

2.
Mangano F, Mangano C, Margiani B, Admakin O . Combining Intraoral and Face Scans for the Design and Fabrication of Computer-Assisted Design/Computer-Assisted Manufacturing (CAD/CAM) Polyether-Ether-Ketone (PEEK) Implant-Supported Bars for Maxillary Overdentures. Scanning. 2019; 2019:4274715. PMC: 6724437. DOI: 10.1155/2019/4274715. View

3.
Tallarico M, Meloni S . Retrospective Analysis on Survival Rate, Template-Related Complications, and Prevalence of Peri-implantitis of 694 Anodized Implants Placed Using Computer-Guided Surgery: Results Between 1 and 10 Years of Follow-Up. Int J Oral Maxillofac Implants. 2017; 32(5):1162-1171. DOI: 10.11607/jomi.5930. View

4.
Meloni S, Tallarico M, Pisano M, Xhanari E, Canullo L . Immediate Loading of Fixed Complete Denture Prosthesis Supported by 4-8 Implants Placed Using Guided Surgery: A 5-Year Prospective Study on 66 Patients with 356 Implants. Clin Implant Dent Relat Res. 2016; 19(1):195-206. DOI: 10.1111/cid.12449. View

5.
Meloni S, Jovanovic S, Urban I, Baldoni E, Pisano M, Tallarico M . Horizontal ridge augmentation using GBR with a native collagen membrane and 1:1 ratio of particulate xenograft and autologous bone: A 3-year after final loading prospective clinical study. Clin Implant Dent Relat Res. 2019; 21(4):669-677. DOI: 10.1111/cid.12808. View