Comparison of Component Placement Accuracy Using Two Intraoperative Fluoroscopic Grid Technologies During Direct Anterior Total Hip Arthroplasty

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2020 Jul 19
PMID 32680756
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Intraoperative fluoroscopy is beneficial when performing total hip arthroplasty (THA) via the direct anterior approach; however, image distortion may influence component placement. A manual gridding system (MGS) and a digital gridding system (DGS) are commercially available, aimed at visually representing or correcting image distortion. Therefore, the purpose of this study is to compare component placement accuracy following direct anterior approach THA when intraoperative fluoroscopy was supplemented with MGS or DGS.

Methods: A retrospective evaluation of acetabular cup abduction (ABD), leg length discrepancy (LLD) and global hip offset difference (GHO) was completed for consecutive patients from 6 week post-THA weight-bearing radiographs. The predefined target LLD and GHO was <10 mm and ABD target was 45° ± 10°. Differences between MGS and DGS were determined by independent t-tests.

Results: The MGS (250 patients, 315 hips) and DGS (183 patients, 218 hips) achieved targeted ABD in 98.7% and 96.8% of cases, respectively, and ABD was significantly lower in the MGS group (45.14 ± 4.03° and 47.01 ± 4.39°, respectively) (P < .001). Compared to MGS, the DGS group averaged significantly higher GHO (3.64 ± 2.44 and 4.45 ± 2.73 mm, respectively, P = .002) but was not significantly different regarding LLD (2.92 ± 2.55 and 3.19 ± 2.46 mm, respectively, P = .275). No significant group difference was noted for percentage within the targeted LLD and GHO; however, 93.5% of DGS and 97.6% of MGS achieved all three (P = .031).

Conclusion: The use of both the MGS and DGS resulted in consistent component placement within the predefined target zone. Although the MGS appeared to be slightly more consistent, these differences are unlikely to be clinically significant.

Citing Articles

Leg length discrepancy after total hip arthroplasty performed by direct anterior approach: a systematic review comparing surgical approaches and strategies for prevention.

Tassinari L, Di Martino A, Brunello M, Rossomando V, Traina F, Faldini C EFORT Open Rev. 2024; 9(8):733-744.

PMID: 39087513 PMC: 11370713. DOI: 10.1530/EOR-23-0116.


Accuracy of two-dimensional digital planning in uncemented primary hip arthroplasty: monocentric analysis of eight hundred implants.

Zampogna B, Parisi F, Zampoli A, Prezioso A, Vorini F, Laudisio A Int Orthop. 2024; 48(8):1979-1985.

PMID: 38622366 DOI: 10.1007/s00264-024-06172-x.


Extended offset stems are infrequently required in anterior approach total hip arthroplasty and low usage does not compromise stability.

Weldon E, Agonias K, DeJesus J, Weldon R, Au D, Nakasone C Arch Orthop Trauma Surg. 2024; 144(5):2365-2372.

PMID: 38512461 DOI: 10.1007/s00402-024-05239-z.


The prevalence of bilateral and ipsilateral radiographic osteoarthritis is high in White, Asian and Native Hawaiian/Pacific Islanders presenting for unilateral knee or hip arthroplasty.

Kop M, Kim N, Shimoda B, Unebasami E, Weldon R, Nakasone C Arch Orthop Trauma Surg. 2024; 144(4):1565-1573.

PMID: 38386068 DOI: 10.1007/s00402-024-05252-2.


Accuracy of Leg Length and Hip Offset Measurements Using a Fluoroscopic Grid During Anterior Approach Total Hip Arthroplasty.

Doehrmann R, Comer B, Chatterji R, Diedring B, Knapp P, Afsari A Arthroplast Today. 2023; 22:101154.

PMID: 37502102 PMC: 10369392. DOI: 10.1016/j.artd.2023.101154.