» Articles » PMID: 38622366

Accuracy of Two-dimensional Digital Planning in Uncemented Primary Hip Arthroplasty: Monocentric Analysis of Eight Hundred Implants

Overview
Journal Int Orthop
Specialty Orthopedics
Date 2024 Apr 15
PMID 38622366
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: In the last decades, there has been a refinement in total hip arthroplasty, which allowed surgeons to achieve the highest performance and better patient outcomes. Preoperative planning in primary hip arthroplasty is an essential step that guides the surgeon in restoring the anatomy and biomechanics of the joint. This study aims to evaluate the accuracy of the 2D digital planning, considering cup sizing, stem sizing, and limb length discrepancy. Additionally, we conducted a multivariable analysis of demographic data and comorbidities to find factors influencing preoperative planning.

Methods: This retrospective study analyzed the planning accuracy in 800 consecutive uncemented primary total hip arthroplasty. We compared the preoperatively planned total hip arthroplasty with postoperative results regarding the planned component size, the implanted size, and the lower limb length restoration. Therefore, we investigated factors influencing planning accuracy: overweight and obesity, sex, age, past medical history, comorbidities, and implant design. All the surgeries were performed in the posterolateral approach by one expert surgeon who did the preoperative planning. The preoperative planning was determined to be (a) exact if the planned and the implanted components were the same size and (b) accurate if exact ± one size. The restoration of postoperative limb length discrepancy was classified into three groups: ± 3 mm, ± 5 mm, and ± 10 mm. This assessment was performed through a digital method 2D based on a standard hip X-ray.

Results: This court of 800 implants showed that planning was exact in 60% of the cups and 44% of the stems and was accurate in 94% of the cups and 80% of the stems. The postoperative limb length discrepancy was ± 3 mm in 91% and ± 5 mm in 97%.

Conclusions: This study showed preoperative 2D digital planning great precision and reliability, and we demonstrated that it was accurate in 94% of the cups and 80% of the stems. Therefore, the preoperative limb length discrepancy analysis was essential to guarantee the recovery of the operated limb's correct length.

Citing Articles

Planning Accuracy and Stem Offset Assessment in Digital Two-Dimensional Versus Three-Dimensional Planning in Cementless Hip Arthroplasty: A Systematic Review and Meta-Analysis.

Parisi F, Zampogna B, Zampoli A, Ferrini A, Albimonti G, Del Monaco A J Clin Med. 2024; 13(21).

PMID: 39518705 PMC: 11546058. DOI: 10.3390/jcm13216566.

References
1.
Colombi A, Schena D, Castelli C . Total hip arthroplasty planning. EFORT Open Rev. 2019; 4(11):626-632. PMC: 6851526. DOI: 10.1302/2058-5241.4.180075. View

2.
Sobieraj M, Rimnac C . Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior. J Mech Behav Biomed Mater. 2009; 2(5):433-43. PMC: 3601552. DOI: 10.1016/j.jmbbm.2008.12.006. View

3.
Tsikandylakis G, Overgaard S, Zagra L, Karrholm J . Global diversity in bearings in primary THA. EFORT Open Rev. 2020; 5(10):763-775. PMC: 7608521. DOI: 10.1302/2058-5241.5.200002. View

4.
Khalifa A, Bakr H . Updates in biomaterials of bearing surfaces in total hip arthroplasty. Arthroplasty. 2022; 3(1):32. PMC: 8796426. DOI: 10.1186/s42836-021-00092-6. View

5.
Rae I, Stimson E, Scheraga H . Nuclear Overhauser effects and the conformation of gramicidin S. Biochem Biophys Res Commun. 1977; 77(1):225-9. DOI: 10.1016/s0006-291x(77)80186-1. View