» Articles » PMID: 32666783

Paper/Soluble Polymer Hybrid-Based Lateral Flow Biosensing Platform for High-Performance Point-of-Care Testing

Overview
Date 2020 Jul 16
PMID 32666783
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

As a global shift continues to occur in high burden diseases toward developing countries, the importance of medical diagnostics based on point-of-care testing (POCT) is rapidly increasing. However, most diagnostic tests that meet clinical standards rely on high-end analyzers in central hospitals. Here, we report the development of a simple, low-cost, mass-producible, highly sensitive/quantitative, automated, and robust paper/soluble polymer hybrid-based lateral flow biosensing platform, paired with a smartphone-based reader, for high-performance POCT. The testing architecture incorporates a polymeric barrier that programs/automates sequential reactions via a polymer dissolving mechanism. The smartphone-based reader with simple opto-mechanical parts offers a stable framework for accurate quantification. Analytical performance of this platform was evaluated by testing human cardiac troponin I (cTnI), a preferred biomarker for the diagnosis of myocardial infarction, in serum/plasma samples. Coupled with catalytic/colorimetric gold-ion amplification, this platform produced results within 20 min with a detection limit of 0.92 pg mL and a coefficient of variation <10%, which is equivalent to the performance of a high-sensitivity standard analyzer, and operated within acceptable levels stipulated by clinical guidelines. Moreover, cTnI clinical sample tests indicate a high correlation ( = 0.981) with the contemporary analyzers, demonstrating the clinical utility of this platform in high-performance POCT.

Citing Articles

Automatically Signal-Enhanced Lateral Flow Immunoassay for Ultrasensitive Salivary Cortisol Detection.

Kim S, Kim M Anal Chem. 2025; 97(5):2707-2713.

PMID: 39895203 PMC: 11822745. DOI: 10.1021/acs.analchem.4c04700.


Deep Learning-Enhanced Paper-Based Vertical Flow Assay for High-Sensitivity Troponin Detection Using Nanoparticle Amplification.

Han G, Goncharov A, Eryilmaz M, Joung H, Ghosh R, Yim G ACS Nano. 2024; 18(41):27933-27948.

PMID: 39365271 PMC: 11483942. DOI: 10.1021/acsnano.4c05153.


Post-Assay Chemical Enhancement for Highly Sensitive Lateral Flow Immunoassays: A Critical Review.

Panferov V, Zherdev A, Dzantiev B Biosensors (Basel). 2023; 13(9).

PMID: 37754100 PMC: 10526817. DOI: 10.3390/bios13090866.


A Quantitative Detection Algorithm for Multi-Test Line Lateral Flow Immunoassay Applied in Smartphones.

Zhang S, Jiang X, Lu S, Yang G, Wu S, Chen L Sensors (Basel). 2023; 23(14).

PMID: 37514695 PMC: 10383061. DOI: 10.3390/s23146401.


Advancement in Paper-Based Electrochemical Biosensing and Emerging Diagnostic Methods.

Benjamin S, de Lima F, do Nascimento V, de Andrade G, Barreto Oria R Biosensors (Basel). 2023; 13(7).

PMID: 37504088 PMC: 10377443. DOI: 10.3390/bios13070689.