» Articles » PMID: 37514695

A Quantitative Detection Algorithm for Multi-Test Line Lateral Flow Immunoassay Applied in Smartphones

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2023 Jul 29
PMID 37514695
Authors
Affiliations
Soon will be listed here.
Abstract

The traditional lateral flow immunoassay (LFIA) detection method suffers from issues such as unstable detection results and low quantitative accuracy. In this study, we propose a novel multi-test line lateral flow immunoassay quantitative detection method using smartphone-based SAA immunoassay strips. Following the utilization of image processing techniques to extract and analyze the pigments on the immunoassay strips, quantitative analysis of the detection results was conducted. Experimental setups with controlled lighting conditions in a dark box were designed to capture samples using smartphones with different specifications for analysis. The algorithm's sensitivity and robustness were validated by introducing noise to the samples, and the detection performance on immunoassay strips using different algorithms was determined. The experimental results demonstrate that the proposed lateral flow immunoassay quantitative detection method based on image processing techniques achieves an accuracy rate of 94.23% on 260 samples, which is comparable to the traditional methods but with higher stability and lower algorithm complexity.

Citing Articles

Evaluating Methods for Aflatoxin B1 Monitoring in Selected Food Crops Within Decentralized Agricultural Systems.

Tanveer H, Glesener H, Su B, Bolsinger B, Krajmalnik-Brown R, Voth-Gaeddert L Toxins (Basel). 2025; 17(1.

PMID: 39852990 PMC: 11769523. DOI: 10.3390/toxins17010037.

References
1.
Gong F, Wei H, Li Q, Liu L, Li B . Evaluation and Comparison of Serological Methods for COVID-19 Diagnosis. Front Mol Biosci. 2021; 8:682405. PMC: 8343015. DOI: 10.3389/fmolb.2021.682405. View

2.
Wahab M, OHaver T . Wavelet transforms in separation science for denoising and peak overlap detection. J Sep Sci. 2020; 43(9-10):1998-2010. DOI: 10.1002/jssc.202000013. View

3.
Portilho A, Gimenes Lima G, De Gaspari E . Enzyme-Linked Immunosorbent Assay: An Adaptable Methodology to Study SARS-CoV-2 Humoral and Cellular Immune Responses. J Clin Med. 2022; 11(6). PMC: 8948777. DOI: 10.3390/jcm11061503. View

4.
Huang L, Tian S, Zhao W, Liu K, Ma X, Guo J . Convolutional Neural Network for Accurate Analysis of Methamphetamine With Upconversion Lateral Flow Biosensor. IEEE Trans Nanobioscience. 2022; 22(1):38-44. DOI: 10.1109/TNB.2022.3143860. View

5.
Han G, Koo H, Ki H, Kim M . Paper/Soluble Polymer Hybrid-Based Lateral Flow Biosensing Platform for High-Performance Point-of-Care Testing. ACS Appl Mater Interfaces. 2020; 12(31):34564-34575. DOI: 10.1021/acsami.0c07893. View