» Articles » PMID: 32384806

Wearable Inertial Sensors to Assess Gait During the 6-Minute Walk Test: A Systematic Review

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 May 10
PMID 32384806
Citations 40
Authors
Affiliations
Soon will be listed here.
Abstract

Wearable sensors are becoming increasingly popular for complementing classical clinical assessments of gait deficits. The aim of this review is to examine the existing knowledge by systematically reviewing a large number of papers focusing on the use of wearable inertial sensors for the assessment of gait during the 6-minute walk test (6MWT), a widely recognized, simple, non-invasive, low-cost and reproducible exercise test. After a systematic search on PubMed and Scopus databases, two raters evaluated the quality of 28 full-text articles. Then, the available knowledge was summarized regarding study design, subjects enrolled (number of patients and pathological condition, if any, age, male/female ratio), sensor characteristics (type, number, sampling frequency, range) and body placement, 6MWT protocol and extracted parameters. Results were critically discussed to suggest future directions for the use of inertial sensor devices in the clinics.

Citing Articles

Convolutional neural network based detection of early stage Parkinson's disease using the six minute walk test.

Choi H, Youm C, Park H, Kim B, Hwang J, Cheon S Sci Rep. 2024; 14(1):22648.

PMID: 39349539 PMC: 11442580. DOI: 10.1038/s41598-024-72648-w.


Development and Assessment of Artificial Intelligence-Empowered Gait Monitoring System Using Single Inertial Sensor.

Zhou J, Mao Q, Yang F, Zhang J, Shi M, Hu Z Sensors (Basel). 2024; 24(18).

PMID: 39338743 PMC: 11436140. DOI: 10.3390/s24185998.


Automatic Detection of Fatigued Gait Patterns in Older Adults: An Intelligent Portable Device Integrating Force and Inertial Measurements with Machine Learning.

Zhang G, Hong T, Li L, Zhang M Ann Biomed Eng. 2024; 53(1):48-58.

PMID: 39136890 PMC: 11782397. DOI: 10.1007/s10439-024-03603-z.


Physical Functioning, Physical Activity, and Variability in Gait Performance during the Six-Minute Walk Test.

Rekant J, Ortmeyer H, Giffuni J, Friedman B, Addison O Sensors (Basel). 2024; 24(14).

PMID: 39066052 PMC: 11280787. DOI: 10.3390/s24144656.


Motor and Respiratory Tele-Rehabilitation in Patients with Long COVID-19 after Hospital Discharge: An Interventional Study.

Cerfoglio S, Verme F, Capodaglio P, Rossi P, Cvetkova V, Boldini G Life (Basel). 2024; 14(7).

PMID: 39063618 PMC: 11277623. DOI: 10.3390/life14070864.


References
1.
Arvidsson D, Fridolfsson J, Borjesson M, Andersen L, Ekblom O, Dencker M . Re-examination of accelerometer data processing and calibration for the assessment of physical activity intensity. Scand J Med Sci Sports. 2019; 29(10):1442-1452. DOI: 10.1111/sms.13470. View

2.
Shema-Shiratzky S, Gazit E, Sun R, Regev K, Karni A, Sosnoff J . Deterioration of specific aspects of gait during the instrumented 6-min walk test among people with multiple sclerosis. J Neurol. 2019; 266(12):3022-3030. DOI: 10.1007/s00415-019-09500-z. View

3.
Dingwell J, Cusumano J, Cavanagh P, Sternad D . Local dynamic stability versus kinematic variability of continuous overground and treadmill walking. J Biomech Eng. 2001; 123(1):27-32. DOI: 10.1115/1.1336798. View

4.
Moher D, Shamseer L, Clarke M, Ghersi D, Liberati A, Petticrew M . Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. Syst Rev. 2015; 4:1. PMC: 4320440. DOI: 10.1186/2046-4053-4-1. View

5.
du Bois R, Albera C, Bradford W, Costabel U, Leff J, Noble P . 6-Minute walk distance is an independent predictor of mortality in patients with idiopathic pulmonary fibrosis. Eur Respir J. 2013; 43(5):1421-9. DOI: 10.1183/09031936.00131813. View