Overview
Specialty Orthopedics
Date 2019 May 19
PMID 31102474
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

This review re-examines the use of accelerometer and oxygen uptake data for the assessment of activity intensity. Accelerometers capture mechanical work, while oxygen uptake captures the energy cost of this work. Frequency filtering needs to be considered when processing acceleration data. A too restrictive filter attenuates the acceleration signal for walking and, to a higher degree, for running. This measurement error affects shorter (children) more than taller (adults) individuals due to their higher movement frequency. Less restrictive filtering includes more movement-related signals and provides measures that better capture mechanical work, but may include more noise. An optimal filter cut-point is determined where most relevant acceleration signals are included. Further, accelerometer placement affects what part of mechanical work being captured. While the waist placement captures total mechanical work and therefore contributes to measures of activity intensity equivalent by age and stature, the thigh and wrist placements capture more internal work and do not provide equivalent measures. Value calibration of accelerometer measures is usually performed using measured oxygen uptake with the metabolic equivalent of task (MET) as reference measure of activity intensity. However, the use of MET is not stringent and is not a measure of activity intensity equivalent by age and stature. A candidate measure is the mass-specific net oxygen uptake, VO net (VO tot - VO stand). To improve measurement of physical activity intensity using accelerometers, research developments are suggested concerning the processing of accelerometer data, use of energy expenditure as reference for activity intensity, and calibration procedure with absolute versus relative intensity.

Citing Articles

Emerging methods for measuring physical activity using accelerometry in children and adolescents with neuromotor disorders: a narrative review.

Petersen B, Erickson K, Kurowski B, Boninger M, Treble-Barna A J Neuroeng Rehabil. 2024; 21(1):31.

PMID: 38419099 PMC: 10903036. DOI: 10.1186/s12984-024-01327-8.


Autonomous motivation, social support, and physical activity in school children: moderating effects of school-based rope skipping sports participation.

Qi Y, Yin Y, Wang X, Zou Y, Liu B Front Public Health. 2024; 12:1295924.

PMID: 38327571 PMC: 10847259. DOI: 10.3389/fpubh.2024.1295924.


Performance of Different Accelerometry-Based Metrics to Estimate Oxygen Consumption during Track and Treadmill Locomotion over a Wide Intensity Range.

Vaha-Ypya H, Bretterhofer J, Husu P, Windhaber J, Vasankari T, Titze S Sensors (Basel). 2023; 23(11).

PMID: 37299803 PMC: 10255337. DOI: 10.3390/s23115073.


Validation of Oura ring energy expenditure and steps in laboratory and free-living.

Kristiansson E, Fridolfsson J, Arvidsson D, Holmang A, Borjesson M, Andersson-Hall U BMC Med Res Methodol. 2023; 23(1):50.

PMID: 36829120 PMC: 9950693. DOI: 10.1186/s12874-023-01868-x.


A theory-based model of cumulative activity.

Phillips K, Stanley K, Fuller D Sci Rep. 2022; 12(1):15635.

PMID: 36115875 PMC: 9482623. DOI: 10.1038/s41598-022-18982-3.