Investigation of Photoplethysmography Behind the Ear for Pulse Oximetry in Hypoxic Conditions with a Novel Device (SPYDR)

Overview
Specialty Biotechnology
Date 2020 Apr 9
PMID 32260393
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Photoplethysmography (PPG) is a valuable technique for noninvasively evaluating physiological parameters. However, traditional PPG devices have significant limitations in high-motion and low-perfusion environments. To overcome these limitations, we investigated the accuracy of a clinically novel PPG site using SPYDR, a new PPG sensor suite, against arterial blood gas (ABG) measurements as well as other commercial PPG sensors at the finger and forehead in hypoxic environments. SPYDR utilizes a reflectance PPG sensor applied behind the ear, between the pinna and the hairline, on the mastoid process, above the sternocleidomastoid muscle, near the posterior auricular artery in a self-contained ear cup system. ABG revealed accuracy of SPYDR with a root mean square error of 2.61% at a 70-100% range, meeting FDA requirements for PPG sensor accuracy. Subjects were also instrumented with SPYDR, as well as finger and forehead PPG sensors, and pulse rate (PR) and oxygen saturation (SpO) were measured and compared at various reduced oxygen profiles with a reduced oxygen breathing device (ROBD). SPYDR was shown to be as accurate as other sensors in reduced oxygen environments with a Pearson's correlation >93% for PR and SpO. In addition, SPYDR responded to changes in SpO up to 50 s faster than PPG measurements at the finger and forehead.

Citing Articles

A Self-Calibrated Single Wavelength Biosensor for Measuring Oxygen Saturation.

Katan M, Pearl O, Tzroya A, Duadi H, Fixler D Biosensors (Basel). 2024; 14(3).

PMID: 38534239 PMC: 10968215. DOI: 10.3390/bios14030132.


A high altitude respiration and SpO2 dataset for assessing the human response to hypoxia.

Zhang X, Zhang Y, Si Y, Gao N, Zhang H, Yang H Sci Data. 2024; 11(1):248.

PMID: 38413602 PMC: 10899206. DOI: 10.1038/s41597-024-03065-x.


An Igor Pro 8.01 Procedure to Analyze Pulse Oximetry during Acute Hypoxia Test in Aircrews.

Alvear-Catalan M, Montiglio C, Perales I, Viscor G, Araneda O Sensors (Basel). 2023; 23(4).

PMID: 36850925 PMC: 9966371. DOI: 10.3390/s23042327.


Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review.

Almarshad M, Islam M, Al-Ahmadi S, BaHammam A Healthcare (Basel). 2022; 10(3).

PMID: 35327025 PMC: 8950880. DOI: 10.3390/healthcare10030547.


Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths.

Martin-Escudero P, Cabanas A, Fuentes-Ferrer M, Galindo-Canales M Biosensors (Basel). 2021; 11(10).

PMID: 34677347 PMC: 8534025. DOI: 10.3390/bios11100391.


References
1.
Abay T, Kyriacou P . Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion. IEEE Trans Biomed Eng. 2015; 62(9):2187-95. DOI: 10.1109/TBME.2015.2417863. View

2.
Mendelson Y, Ochs B . Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography. IEEE Trans Biomed Eng. 1988; 35(10):798-805. DOI: 10.1109/10.7286. View

3.
Shafqat K, Langford R, Pal S, Kyriacou P . Estimation of venous oxygenation saturation using the finger Photoplethysmograph (PPG) waveform. Annu Int Conf IEEE Eng Med Biol Soc. 2013; 2012:2905-8. DOI: 10.1109/EMBC.2012.6346571. View

4.
Venema B, Schiefer J, Blazek V, Blanik N, Leonhardt S . Evaluating Innovative In-Ear Pulse Oximetry for Unobtrusive Cardiovascular and Pulmonary Monitoring During Sleep. IEEE J Transl Eng Health Med. 2016; 1:2700208. PMC: 4819232. DOI: 10.1109/JTEHM.2013.2277870. View

5.
Allen J . Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007; 28(3):R1-39. DOI: 10.1088/0967-3334/28/3/R01. View