» Articles » PMID: 32219207

High-Precision Control of Plasma Drug Levels Using Feedback-Controlled Dosing

Overview
Specialty Biochemistry
Date 2020 Mar 29
PMID 32219207
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

By, in effect, rendering pharmacokinetics an experimentally adjustable parameter, the ability to perform feedback-controlled dosing informed by high-frequency in vivo drug measurements would prove a powerful tool for both pharmacological research and clinical practice. Efforts to this end, however, have historically been thwarted by an inability to measure in vivo drug levels in real time and with sufficient convenience and temporal resolution. In response, we describe a closed-loop, feedback-controlled delivery system that uses drug level measurements provided by an in vivo electrochemical aptamer-based (E-AB) sensor to adjust dosing rates every 7 s. The resulting system supports the maintenance of either constant or predefined time-varying plasma drug concentration profiles in live rats over many hours. For researchers, the resultant high-precision control over drug plasma concentrations provides an unprecedented opportunity to (1) map the relationships between pharmacokinetics and clinical outcomes, (2) eliminate inter- and intrasubject metabolic variation as a confounding experimental variable, (3) accurately simulate human pharmacokinetics in animal models, and (4) measure minute-to-minute changes in a drug's pharmacokinetic behavior in response to changing health status, diet, drug-drug interactions, or other intrinsic and external factors. In the clinic, feedback-controlled drug delivery would improve our ability to accurately maintain therapeutic drug levels in the face of large, often unpredictable intra- and interpatient metabolic variation. This, in turn, would improve the efficacy and safety of therapeutic intervention, particularly for the most gravely ill patients, for whom metabolic variability is highest and the margin for therapeutic error is smallest.

Citing Articles

Enhancing immunotherapy with tumour-responsive nanomaterials.

Linderman S, DeRidder L, Sanjurjo L, Foote M, Alonso M, Kirtane A Nat Rev Clin Oncol. 2025; .

PMID: 40050505 DOI: 10.1038/s41571-025-01000-6.


Therapeutic Drug Distribution across the Mouse Brain Is Heterogeneous as Revealed by In Vivo, Spatially Resolved Aptamer-Based Sensing.

Scida K, Ornelas-Gatdula E, DePasquale M, Carr G, Arroyo-Curras N ACS Pharmacol Transl Sci. 2025; 8(2):435-445.

PMID: 39990862 PMC: 11843511. DOI: 10.1021/acsptsci.4c00579.


Feedback control over plasma drug concentrations achieves rapid and accurate control over solid-tissue drug concentrations.

Emmons N, Duman Z, Erdal M, Kippin T, Hespanha J, Plaxco K Res Sq. 2025; .

PMID: 39975897 PMC: 11838736. DOI: 10.21203/rs.3.rs-5868915/v1.


Effects of Physiological-Scale Variation in Cations, pH, and Temperature on the Calibration of Electrochemical Aptamer-Based Sensors.

Fetter L, McDonough M, Kippin T, Plaxco K ACS Sens. 2024; 9(12):6675-6684.

PMID: 39570094 PMC: 11855119. DOI: 10.1021/acssensors.4c02274.


Continuous Biosensor Based on Particle Motion: How Does the Concentration Measurement Precision Depend on Time Scale?.

Lubken R, Lin Y, Haenen S, Bergkamp M, Yan J, Nommensen P ACS Sens. 2024; 9(9):4924-4933.

PMID: 39166946 PMC: 11443519. DOI: 10.1021/acssensors.4c01586.


References
1.
White R, Phares N, Lubin A, Xiao Y, Plaxco K . Optimization of electrochemical aptamer-based sensors via optimization of probe packing density and surface chemistry. Langmuir. 2008; 24(18):10513-8. PMC: 2674396. DOI: 10.1021/la800801v. View

2.
Nakatsuka N, Yang K, Abendroth J, Cheung K, Xu X, Yang H . Aptamer-field-effect transistors overcome Debye length limitations for small-molecule sensing. Science. 2018; 362(6412):319-324. PMC: 6663484. DOI: 10.1126/science.aao6750. View

3.
Damsma G, Westerink B, DE VRIES J, Van Den Berg C, Horn A . Measurement of acetylcholine release in freely moving rats by means of automated intracerebral dialysis. J Neurochem. 1987; 48(5):1523-8. DOI: 10.1111/j.1471-4159.1987.tb05695.x. View

4.
Naylor E, Aillon D, Gabbert S, Harmon H, Johnson D, Wilson G . Simultaneous real-time measurement of EEG/EMG and L-glutamate in mice: A biosensor study of neuronal activity during sleep. J Electroanal Chem (Lausanne). 2016; 656(1-2):106-113. PMC: 4827928. DOI: 10.1016/j.jelechem.2010.12.031. View

5.
Mastrototaro J . The MiniMed continuous glucose monitoring system. Diabetes Technol Ther. 2001; 2 Suppl 1:S13-8. DOI: 10.1089/15209150050214078. View