» Articles » PMID: 31667134

Gradient- and Spin-echo (GRASE) MR Imaging: a Long-existing Technology That May Find Wide Applications in Modern Era

Overview
Specialty Radiology
Date 2019 Nov 1
PMID 31667134
Citations 9
Authors
Affiliations
Soon will be listed here.
Citing Articles

Understanding cellular proliferation activity in breast cancer using multi-compartment model of transverse relaxation time mapping on 3T MRI.

Nkonde K, Cheung S, Senn N, He J Front Oncol. 2025; 15:1482112.

PMID: 39949748 PMC: 11821498. DOI: 10.3389/fonc.2025.1482112.


A single 1-min brain MRI scan for generating multiple synthetic image contrasts in awake children from quantitative relaxometry maps.

Kilpattu Ramaniharan A, Pednekar A, Parikh N, Nagaraj U, Manhard M Pediatr Radiol. 2024; 55(2):312-323.

PMID: 39692886 DOI: 10.1007/s00247-024-06113-1.


Enhanced Myocardial Tissue Visualization: A Comparative Cardiovascular Magnetic Resonance Study of Gradient-Spin Echo-STIR and Conventional STIR Imaging.

Dehghani S, Shirani S, Jazayeri Gharebagh E Int J Biomed Imaging. 2024; 2024:8456669.

PMID: 38590625 PMC: 11001468. DOI: 10.1155/2024/8456669.


Deep learning-based reconstruction and 3D hybrid profile order technique for MRCP at 3T: evaluation of image quality and acquisition time.

Shiraishi K, Nakaura T, Uetani H, Nagayama Y, Kidoh M, Kobayashi N Eur Radiol. 2023; 33(11):7585-7594.

PMID: 37178197 DOI: 10.1007/s00330-023-09703-z.


Predicting the image quality of respiratory-gated and breath-hold 3D MRCP from the breathing curve: a prospective study.

Wang K, Li X, Liu J, Guo X, Li W, Cao X Eur Radiol. 2022; 33(6):4333-4343.

PMID: 36543903 DOI: 10.1007/s00330-022-09293-2.


References
1.
Itatani R, Namimoto T, Kajihara H, Yoshimura A, Katahira K, Nasu J . Preoperative evaluation of the cystic duct for laparoscopic cholecystectomy: comparison of navigator-gated prospective acquisition correction- and conventional respiratory-triggered techniques at free-breathing 3D MR cholangiopancreatography. Eur Radiol. 2013; 23(7):1911-8. DOI: 10.1007/s00330-013-2790-5. View

2.
Yoshida M, Nakaura T, Inoue T, Tanoue S, Takada S, Utsunomiya D . Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE?. Eur Radiol. 2018; 28(6):2436-2443. DOI: 10.1007/s00330-017-5240-y. View

3.
Feinberg D, Oshio K . GRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique. Radiology. 1991; 181(2):597-602. DOI: 10.1148/radiology.181.2.1924811. View

4.
Meyers S, Kolind S, MacKay A . Simultaneous measurement of total water content and myelin water fraction in brain at 3T using a T relaxation based method. Magn Reson Imaging. 2016; 37:187-194. DOI: 10.1016/j.mri.2016.12.001. View

5.
Feinberg D, Johnson G, Kiefer B . Increased flexibility in GRASE imaging by k space-banded phase encoding. Magn Reson Med. 1995; 34(2):149-55. DOI: 10.1002/mrm.1910340204. View