» Articles » PMID: 29335869

Magnetic Resonance Cholangiopancreatography with GRASE Sequence at 3.0T: Does It Improve Image Quality and Acquisition Time As Compared with 3D TSE?

Overview
Journal Eur Radiol
Specialty Radiology
Date 2018 Jan 17
PMID 29335869
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The current study evaluated the clinical usefulness of the gradient and spin-echo (GRASE) sequence with single breath-hold in 3.0 T magnetic resonance cholangiopancreatography (MRCP). We compared the acquisition time and image quality between GRASE and breath navigator-triggered 3D turbo spin echo (3D TSE).

Methods: We examined 54 consecutive patients who underwent MRCP with GRASE and 3D TSE. We compared the image acquisition time and contrast-to-noise ratio (CNR) between the common bile duct (CBD) and liver. Overall image quality, blurring, motion artifacts and CBD visibility were scored on a 4-point scale by two radiologists. Paired t-tests were used to compare the variables.

Results: The mean image acquisition time was 95 % shorter with the GRASE than with 3D TSE (GRASE: 20 s; 3D TSE: 6 min 27 s). The CNR of GRASE was significantly higher than that of 3D TSE (GRASE: 25.4 ± 13.9 vs. 3D TSE: 18.2 ± 9.6, p < 0.01). All qualitative scores for GRASE were significantly better than those for 3D TSE.

Conclusions: 3.0 T MRCP with GRASE sequence with single breath-hold significantly improved the CNR of CBD with a 95 % shorter acquisition time compared with conventional 3D MRCP with 3D TSE.

Key Points: • MRCP acquisition time was 95% shorter with GRASE than with 3D TSE. • Overall image quality of GRASE was significantly better than 3D TSE. • Pancreaticobiliary tree visibility with GRASE was better than that with 3D TSE.

Citing Articles

Magnetic resonance cholangiopancreatography at 5.0 T: quantitative and qualitative comparison with 3.0 T.

Yin L, Li Z, Shang M, Li Z, Tang B, Yu D BMC Med Imaging. 2024; 24(1):331.

PMID: 39639207 PMC: 11622504. DOI: 10.1186/s12880-024-01512-0.


Enhanced Myocardial Tissue Visualization: A Comparative Cardiovascular Magnetic Resonance Study of Gradient-Spin Echo-STIR and Conventional STIR Imaging.

Dehghani S, Shirani S, Jazayeri Gharebagh E Int J Biomed Imaging. 2024; 2024:8456669.

PMID: 38590625 PMC: 11001468. DOI: 10.1155/2024/8456669.


Feasibility study of super-resolution deep learning-based reconstruction using k-space data in brain diffusion-weighted images.

Matsuo K, Nakaura T, Morita K, Uetani H, Nagayama Y, Kidoh M Neuroradiology. 2023; 65(11):1619-1629.

PMID: 37673835 DOI: 10.1007/s00234-023-03212-y.


Accelerated 3D MR neurography of the brachial plexus using deep learning-constrained compressed sensing.

Hu S, Xiao Y, Peng W, Zeng W, Zhang Y, Zhang X Eur Radiol. 2023; 34(2):842-851.

PMID: 37606664 DOI: 10.1007/s00330-023-09996-0.


Deep learning-based reconstruction and 3D hybrid profile order technique for MRCP at 3T: evaluation of image quality and acquisition time.

Shiraishi K, Nakaura T, Uetani H, Nagayama Y, Kidoh M, Kobayashi N Eur Radiol. 2023; 33(11):7585-7594.

PMID: 37178197 DOI: 10.1007/s00330-023-09703-z.


References
1.
Rockwell D, Melhem E, Bhatia R . GRASE (gradient- and spin-echo) MR of the brain. AJNR Am J Neuroradiol. 1997; 18(10):1923-8. PMC: 8337352. View

2.
Aube C, Delorme B, Yzet T, Burtin P, Lebigot J, Pessaux P . MR cholangiopancreatography versus endoscopic sonography in suspected common bile duct lithiasis: a prospective, comparative study. AJR Am J Roentgenol. 2004; 184(1):55-62. DOI: 10.2214/ajr.184.1.01840055. View

3.
Sprinkart A, Luetkens J, Traber F, Doerner J, Gieseke J, Schnackenburg B . Gradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping. J Cardiovasc Magn Reson. 2015; 17:12. PMC: 4326516. DOI: 10.1186/s12968-015-0127-z. View

4.
Kinner S, Dechene A, Ladd S, Zopf T, de Dechene E, Gerken G . Comparison of different MRCP techniques for the depiction of biliary complications after liver transplantation. Eur Radiol. 2010; 20(7):1749-56. DOI: 10.1007/s00330-010-1714-x. View

5.
Jung G, Krahe T, Kugel H, Gieseke J, Hahn U, Walter C . Prospective comparison of fast SE and GRASE sequences and echo planar imaging with conventional SE sequences in the detection of focal liver lesions at 1.0 T. J Comput Assist Tomogr. 1997; 21(3):341-7. DOI: 10.1097/00004728-199705000-00002. View