» Articles » PMID: 3135095

Precision of Dual-photon Absorptiometry

Overview
Specialty Pathology
Date 1988 May 1
PMID 3135095
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Precision of dual-photon absorptiometry (DPA) measurements was determined in a lumbar spine phantom and in humans. Approximately half of the measurements were made before and half after a 153gadolinium source change. The phantom was measured with different amounts of acrylic, which simulates human soft tissue, in order to evaluate the influence of body thickness on bone mineral density (BMD). Results of scans analyzed with two software versions from Lunar Radiation Corp., the widely used 08B and a prototype 08C, are compared. DPA with a cold source significantly overestimated BMD in the phantom in the presence of large amounts (more than 25 cm) of soft tissue equivalent with version 08B but not with the newer version 08C. Similarly, in nine subjects, there was a significant decrease in spine BMD after a source change when scans were analyzed with version 08B (mean difference 0.026 g/cm2, P = 0.002) but not with 08C (0.01 g/cm2, P = 0.234). No systematic effect of source change on femoral BMD measurements was observed. The SD of the mean difference of two measurements of the nine subjects was 0.019 g/cm2 (1.6% of the mean value) for the spine with software version 08B and 0.024 g/cm2 (2.0%) with version 08C, 0.03 g/cm2 (3.3%) for the femur neck, 0.03 g/cm2 (4.0%) for the greater trochanter, and 0.04 g/cm2 (4.9%) for Ward's triangle region of the proximal femur. The spine phantom was scanned on two other commercial bone densitometers in order to assess inter-instrument variation.(ABSTRACT TRUNCATED AT 250 WORDS)

Citing Articles

Bone mineral measurements of subchondral and trabecular bone in healthy and osteoporotic rabbits.

Castaneda S, Largo R, Calvo E, Rodriguez-Salvanes F, Marcos M, Diaz-Curiel M Skeletal Radiol. 2005; 35(1):34-41.

PMID: 16247642 DOI: 10.1007/s00256-005-0022-z.


Tooth loss and skeletal bone density in healthy postmenopausal women.

Krall E, Dawson-Hughes B, Papas A, Garcia R Osteoporos Int. 1994; 4(2):104-9.

PMID: 8003839 DOI: 10.1007/BF01623233.


Exercise and bone mineral density.

Chilibeck P, Sale D, Webber C Sports Med. 1995; 19(2):103-22.

PMID: 7747001 DOI: 10.2165/00007256-199519020-00003.


Correction of the effects of source, source strength, and soft-tissue thickness on spine dual-photon absorptiometry measurements.

Dawson-Hughes B, Deehr M, Berger P, Dallal G, Sadowski L Calcif Tissue Int. 1989; 44(4):251-7.

PMID: 2501007 DOI: 10.1007/BF02553759.


Nondestructive measurement of bone mineral in femurs from ovariectomized rats.

Kimmel D, Wronski T Calcif Tissue Int. 1990; 46(2):101-10.

PMID: 2105147 DOI: 10.1007/BF02556093.


References
1.
Dawson-Hughes B, Jacques P, Shipp C . Dietary calcium intake and bone loss from the spine in healthy postmenopausal women. Am J Clin Nutr. 1987; 46(4):685-7. DOI: 10.1093/ajcn/46.4.685. View

2.
Leblanc A, Evans H, Marsh C, Schneider V, Johnson P, JHINGRAN S . Precision of dual photon absorptiometry measurements. J Nucl Med. 1986; 27(8):1362-5. View

3.
Wahner H, Dunn W, Mazess R, Towsley M, Lindsay R, Markhard L . Dual-photon Gd-153 absorptiometry of bone. Radiology. 1985; 156(1):203-6. DOI: 10.1148/radiology.156.1.4001406. View

4.
Nilas L, Borg J, Gotfredsen A, Christiansen C . Comparison of single- and dual-photon absorptiometry in postmenopausal bone mineral loss. J Nucl Med. 1985; 26(11):1257-62. View

5.
Awbrey B, Jacobson P, Grubb S, McCartney W, Vincent L, TALMAGE R . Bone density in women: a modified procedure for measurement of distal radial density. J Orthop Res. 1984; 2(4):314-21. DOI: 10.1002/jor.1100020402. View