» Articles » PMID: 31004219

RR Interval Signal Quality of a Heart Rate Monitor and an ECG Holter at Rest and During Exercise

Overview
Specialty Physiology
Date 2019 Apr 21
PMID 31004219
Citations 111
Authors
Affiliations
Soon will be listed here.
Abstract

This study was designed to examine the RR interval signal qualities of a Holter device and a heart rate chest belt monitor at rest and during exercise. Ten healthy individuals completed five low- to high-intensity activities while simultaneously using the medilog AR12plus  Holter monitor and the Polar H10 heart rate monitor. The RR interval signal quality was based on the quantification of the missing RR intervals and RR interval detection errors. Therefore, both measurement systems were compared against visual inspection of the raw electrocardiography signal. The missing and wrong R-wave peak detections were counted manually for both measurement systems. RR interval signal quality was defined as the relative number of correctly detected RR intervals. Overall, RR interval signal qualities of 94.6% and 99.6% were demonstrated for the medilog AR12plus  and the Polar H10. During the high-intensity activities, the RR interval signal quality of the medilog AR12plus  dropped to 89.8%, whereas the Polar H10 maintained a signal quality of 99.4%. The correlation between both systems was high (r = 0.997, p > 0.001). The excellent RR interval signal quality during low- to moderate-intensity activities in the medilog AR12plus  and during low- to high-intensity activities in the Polar H10 demonstrates both measurement systems' validity for the detection of RR intervals throughout a wide range of activities. A simple chest strap such as the Polar H10 might be recommended as the gold standard for RR interval assessments if intense activities with strong body movements are investigated.

Citing Articles

The Feasibility of Ambulatory Heart Rate Variability Monitoring in Non-Suicidal Self-Injury.

van Hoorn A, Mankee-Williams A, Lewis G, Mellili R, Eccles J, Ottaviani C Healthc Technol Lett. 2025; 12(1):e70007.

PMID: 40027108 PMC: 11868733. DOI: 10.1049/htl2.70007.


Randomized Controlled Trial: Preliminary Investigation of the Impact of High-Intensity Treadmill Gait Training on Recovery Among Persons with Traumatic Brain Injury.

Shick T, Perkins C, Paul A, Martinez M, Joyce J, Beach K Neurotrauma Rep. 2025; 6(1):82-92.

PMID: 39882311 PMC: 11773168. DOI: 10.1089/neur.2024.0169.


Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.

Ceugniez M, Devanne H, Hermand E JMIR Mhealth Uhealth. 2025; 13():e54871.

PMID: 39789790 PMC: 11735015. DOI: 10.2196/54871.


Validation of a Wearable Sensor Prototype for Measuring Heart Rate to Prescribe Physical Activity: Cross-Sectional Exploratory Study.

Loro F, Martins R, Ferreira J, de Araujo C, Prade L, Both C JMIR Biomed Eng. 2024; 9:e57373.

PMID: 39661434 PMC: 11669869. DOI: 10.2196/57373.


Validity of a Consumer-Based Wearable to Measure Clinical Parameters in Patients With Chronic Obstructive Pulmonary Disease and Healthy Controls: Observational Study.

Hermans F, Arents E, Blondeel A, Janssens W, Cardinaels N, Calders P JMIR Mhealth Uhealth. 2024; 12:e56027.

PMID: 39504450 PMC: 11559788. DOI: 10.2196/56027.


References
1.
Hedelin R, Wiklund U, Bjerle P, Henriksson-Larsen K . Cardiac autonomic imbalance in an overtrained athlete. Med Sci Sports Exerc. 2000; 32(9):1531-3. DOI: 10.1097/00005768-200009000-00001. View

2.
Mourot L, Bouhaddi M, Perrey S, Cappelle S, Henriet M, Wolf J . Decrease in heart rate variability with overtraining: assessment by the Poincaré plot analysis. Clin Physiol Funct Imaging. 2004; 24(1):10-8. DOI: 10.1046/j.1475-0961.2003.00523.x. View

3.
Kingsley M, Lewis M, Marson R . Comparison of Polar 810s and an ambulatory ECG system for RR interval measurement during progressive exercise. Int J Sports Med. 2005; 26(1):39-44. DOI: 10.1055/s-2004-817878. View

4.
Gamelin F, Berthoin S, Bosquet L . Validity of the polar S810 heart rate monitor to measure R-R intervals at rest. Med Sci Sports Exerc. 2006; 38(5):887-93. DOI: 10.1249/01.mss.0000218135.79476.9c. View

5.
Nunan D, Jakovljevic D, Donovan G, Hodges L, Sandercock G, Brodie D . Levels of agreement for RR intervals and short-term heart rate variability obtained from the Polar S810 and an alternative system. Eur J Appl Physiol. 2008; 103(5):529-37. DOI: 10.1007/s00421-008-0742-6. View