Optimization of Second Window Indocyanine Green for Intraoperative Near-Infrared Imaging of Thoracic Malignancy
Overview
Gynecology & Obstetrics
Authors
Affiliations
Background: Near-infrared (NIR) imaging using the second time window of indocyanine green (ICG) allows localization of pulmonary, pleural, and mediastinal malignancies during surgery. Based on empirical evidence, we hypothesized that different histologic tumor types fluoresce optimally at different ICG doses.
Study Design: Patients with thoracic tumors biopsy-proven or suspicious for malignancy were enrolled in an NIR imaging clinical trial. Patients received a range of ICG doses 1 day before surgery: 1 mg/kg (n = 8), 2 mg/kg (n = 8), 3 mg/kg (n = 13), 4 mg/kg (n = 8), and 5 mg/kg (n = 8). Intraoperatively, NIR imaging was performed. The endpoint was to identify the highest tumor-to-background fluorescence ratio (TBR) for each tumor type at each dose. Final pathology confirmed tumor histology.
Results: Of 45 patients, 41 had malignancies (18 non-small cell lung cancers [NSCLC], 3 pulmonary neuroendocrine tumors, 13 thoracic metastases, 4 thymomas, 3 mesotheliomas). At doses of 4 to 5 mg/kg, the TBR from primary NSCLC vs other malignancies was no different (2.70 vs 3.21, p = 1.00). At doses of 1 to 3 mg/kg, the TBR was greater for the NSCLCs (3.19 vs 1.49, p = 0.0006). Background fluorescence from the heart or ribs was observed in 1 of 16 cases at 1 to 2 mg/kg, 5 of 13 cases at 3 mg/kg, and 14 of 16 cases at 4 to 5 mg/kg; this was a major determinant of dose optimization.
Conclusions: This is the first study to demonstrate that the optimal NIR contrast agent dose varies by tumor histology. Lower dose ICG (2 to 3 mg/kg) is superior for nonprimary lung cancers, and high dose ICG (4 to 5 mg/kg) is superior for lung cancers. This will have major implications as more intraoperative imaging trials surface in other specialties, will significantly reduce costs and may facilitate wider application.
Affordable Small Molecules as Promising Fluorescent Labels for Biomolecules.
Eustaquio R, Ramalho J, Arantes S, Candeias A, Caldeira A, Pereira A Molecules. 2024; 29(22).
PMID: 39598627 PMC: 11596234. DOI: 10.3390/molecules29225237.
Dai B, Yu A, Zhao G, Wang Y, Zhou Y, Ni K J Thorac Dis. 2024; 16(10):7192-7203.
PMID: 39552905 PMC: 11565355. DOI: 10.21037/jtd-24-1502.
Progression in Near-Infrared Fluorescence Imaging Technology for Lung Cancer Management.
Chen X, Li Y, Su J, Zhang L, Liu H Biosensors (Basel). 2024; 14(10).
PMID: 39451714 PMC: 11506746. DOI: 10.3390/bios14100501.
Dose Optimization of Intravenous Indocyanine Green for Malignant Lung Tumor Localization.
Ujiie H, Chiba R, Sasaki A, Nomura S, Shiiya H, Otsuka S J Clin Med. 2024; 13(10).
PMID: 38792349 PMC: 11122526. DOI: 10.3390/jcm13102807.
Mechanisms of delayed indocyanine green fluorescence and applications to clinical disease processes.
Zajac J, Liu A, Hassan S, Gibson A Surgery. 2024; 176(2):386-395.
PMID: 38749795 PMC: 11246809. DOI: 10.1016/j.surg.2024.03.053.