» Articles » PMID: 30404327

Fabrication and Microassembly of a Mm-Sized Floating Probe for a Distributed Wireless Neural Interface

Overview
Publisher MDPI
Date 2018 Nov 9
PMID 30404327
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

A new class of wireless neural interfaces is under development in the form of tens to hundreds of mm-sized untethered implants, distributed across the target brain region(s). Unlike traditional interfaces that are tethered to a centralized control unit and suffer from micromotions that may damage the surrounding neural tissue, the new free-floating wireless implantable neural recording (FF-WINeR) probes will be stand-alone, directly communicating with an external interrogator. Towards development of the FF-WINeR, in this paper we describe the micromachining, microassembly, and hermetic packaging of 1-mm³ passive probes, each of which consists of a thinned micromachined silicon die with a centered Ø(diameter) 130 μm through-hole, an Ø81 μm sharpened tungsten electrode, a 7-turn gold wire-wound coil wrapped around the die, two 0201 surface mount capacitors on the die, and parylene-C/Polydimethylsiloxane (PDMS) coating. The fabricated passive probe is tested under a 3-coil inductive link to evaluate power transfer efficiency (PTE) and power delivered to a load (PDL) for feasibility assessment. The minimum PTE/PDL at 137 MHz were 0.76%/240 μW and 0.6%/191 μW in the air and lamb head medium, respectively, with coil separation of 2.8 cm and 9 kΩ receiver (Rx) loading. Six hermetically sealed probes went through wireless hermeticity testing, using a 2-coil inductive link under accelerated lifetime testing condition of 85 °C, 1 atm, and 100%RH. The mean-time-to-failure (MTTF) of the probes at 37 °C is extrapolated to be 28.7 years, which is over their lifetime.

Citing Articles

Fabrication and Assembly Techniques for Sub-mm Battery-Free Epicortical Implants.

Khalifa A, Nasrollahpour M, Nezaratizadeh A, Sha X, Stanacevic M, Sun N Micromachines (Basel). 2023; 14(2).

PMID: 36838175 PMC: 9966084. DOI: 10.3390/mi14020476.


Injectable wireless microdevices: challenges and opportunities.

Khalifa A, Lee S, Molnar A, Cash S Bioelectron Med. 2021; 7(1):19.

PMID: 34937565 PMC: 8697496. DOI: 10.1186/s42234-021-00080-w.


A Scalable and Low Stress Post-CMOS Processing Technique for Implantable Microsensors.

Lee A, Lee J, Laiwalla F, Leung V, Huang J, Nurmikko A Micromachines (Basel). 2020; 11(10).

PMID: 33028005 PMC: 7600457. DOI: 10.3390/mi11100925.


Hybrid Coils-Based Wireless Power Transfer for Intelligent Sensors.

Mahmood M, Mohammed S, Gharghan S, Al-Naji A, Chahl J Sensors (Basel). 2020; 20(9).

PMID: 32365800 PMC: 7248994. DOI: 10.3390/s20092549.


Microscopic sensors using optical wireless integrated circuits.

Cortese A, Smart C, Wang T, Reynolds M, Norris S, Ji Y Proc Natl Acad Sci U S A. 2020; 117(17):9173-9179.

PMID: 32303653 PMC: 7196798. DOI: 10.1073/pnas.1919677117.


References
1.
Kiani M, Ghovanloo M . The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission. IEEE Trans Circuits Syst I Regul Pap. 2014; 59(9):2065-2074. PMC: 3969023. DOI: 10.1109/TCSI.2011.2180446. View

2.
Kim S, Tathireddy P, Normann R, Solzbacher F . Thermal impact of an active 3-D microelectrode array implanted in the brain. IEEE Trans Neural Syst Rehabil Eng. 2008; 15(4):493-501. DOI: 10.1109/TNSRE.2007.908429. View

3.
Biran R, Martin D, Tresco P . The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull. J Biomed Mater Res A. 2007; 82(1):169-78. DOI: 10.1002/jbm.a.31138. View

4.
Turner J, Shain W, Szarowski D, Andersen M, Martins S, Isaacson M . Cerebral astrocyte response to micromachined silicon implants. Exp Neurol. 1999; 156(1):33-49. DOI: 10.1006/exnr.1998.6983. View

5.
Ahn D, Ghovanloo M . Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants. IEEE Trans Biomed Circuits Syst. 2015; 10(1):125-37. DOI: 10.1109/TBCAS.2014.2370794. View